ArticleRadiological physics and technology2022
Detectability of category 3 or higher microcalcifications on digital mammograms: a comparative study between 5-MP color and monochrome liquid crystal display monitors.
Article in Radiological physics and technology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study explored the detectability of category 3 or higher microcalcifications using 5-MP color and monochrome monitors. Contrast detail mammography phantom with polymethyl methacrylate (PMMA) images were observed in color and monochrome by five radiographers, and the image quality figures (IQF) were calculated based on the gold disc locations identified. Five radiographers and two radiologists observed 200 mammograms from 100 patients (including 36 with microcalcifications) and rated the microcalcifications. The results were analyzed using area under the curve (AUC) and jackknife resampling. A paired t test was used for statistical analysis (p < 0.05). The mean IQF of color and monochrome monitors were 10.73 and 10.49 (30 mm PMMA, p = 0.653) and 8.47 and 8.74 (50 mm PMMA, p = 0.774), respectively. The mean AUC of color and monochrome monitors were 0.917 and 0.936 (p = 0.335), respectively, with windowing and magnification. The detectability of microcalcifications was not significantly different between the monitors.
Indexed as
Identifiers
36076142What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.