ArticleJournal of synchrotron radiation2022
Environmental control for X-ray nanotomography.
Article in Journal of synchrotron radiation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- In situ ptychographic x-ray nanotomography of temperature-controlled crystallization processes.Nature communications · 2026Article
- In situ ptychographic nanotomography captures activation, mobility, and deactivation of supported catalysts.Nature communications · 2026Article
- The hard X-ray ptychography endstation at the Taiwan Photon Source.Journal of synchrotron radiation · 2026Article
- A high-temperature furnace for multimodal synchrotron-based X-ray microscopy and diffraction imaging.Journal of synchrotron radiation · 2026Article
- Spatiotemporal mapping of alloy mesostructure dynamics via multimodal coherent X-ray diffraction imaging.Proceedings of the National Academy of Sciences of the United States of America · 2025Article
- Design and implementation of a climate chamber for moisture sensitive nanotomography of biological samples.Journal of synchrotron radiation · 2025Article
- Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
Abstract
The acquisition speed and spatial resolution of X-ray nanotomography have continuously improved over the last decades. Coherent diffraction-based techniques breach the 10 nm resolution barrier frequently and thus pose stringent demands on sample positioning accuracy and stability. At the same time there is an increasing desire to accommodate in situ or operando measurements. Here, an environmental control system for X-ray nanotomography is introduced to regulate the temperature of a sample from room temperature up to 850°C in a controlled atmospheric composition. The system allows for a 360° sample rotation, permitting tomographic studies in situ or operando free of missing wedge constraints. The system is implemented and available at the flOMNI microscope at the Swiss Light Source. In addition to the environmental control system itself, the related modifications of flOMNI are described. Tomographic measurements of a nanoporous gold sample at 50°C and 600°C at a resolution of sub-20 nm demonstrate the performance of the device.
Indexed as
Identifiers
What OpenQuestion holds