Evidence map›Paper›PMID 36073881›Full record

ArticleJournal of synchrotron radiation2022

Environmental control for X-ray nanotomography.

Mirko Holler, Tomas Aidukas, Lars Heller, Christian Appel, Nicholas W Phillips, Elisabeth Müller-Gubler, Manuel Guizar-Sicairos, Jörg Raabe, Johannes Ihli

Abstract read
In one paragraph

Article in Journal of synchrotron radiation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Spatiotemporal mapping of alloy mesostructure dynamics via multimodal coherent X-ray diffraction imaging.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mirko HollerPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.ORCID 0000-0001-8141-0148
Tomas AidukasPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.
Lars HellerPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.
Christian AppelPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.ORCID 0000-0002-6050-3836
Nicholas W PhillipsPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.ORCID 0000-0002-9742-7937
Elisabeth Müller-GublerPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.
Manuel Guizar-SicairosPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.ORCID 0000-0002-8293-3634
Jörg RaabePaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.ORCID 0000-0002-2071-6896
Johannes IhliPaul Scherrer Institut, Forschungsstrasse 111, Villigen PSI, Aargau 5232, Switzerland.

Funding

H2020 Marie Sklodowska-Curie Actions 884104Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung 200021_196898Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung PZ00P2_179886
6 · The paper itself

Abstract

The acquisition speed and spatial resolution of X-ray nanotomography have continuously improved over the last decades. Coherent diffraction-based techniques breach the 10 nm resolution barrier frequently and thus pose stringent demands on sample positioning accuracy and stability. At the same time there is an increasing desire to accommodate in situ or operando measurements. Here, an environmental control system for X-ray nanotomography is introduced to regulate the temperature of a sample from room temperature up to 850°C in a controlled atmospheric composition. The system allows for a 360° sample rotation, permitting tomographic studies in situ or operando free of missing wedge constraints. The system is implemented and available at the flOMNI microscope at the Swiss Light Source. In addition to the environmental control system itself, the related modifications of flOMNI are described. Tomographic measurements of a nanoporous gold sample at 50°C and 600°C at a resolution of sub-20 nm demonstrate the performance of the device.

Indexed as

environmental controlin situ nano-tomographyptychographic tomographyptychography

Identifiers

PMID36073881
PMCPMC9455200

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.