Evidence map›Paper›PMID 36072256›Full record

ArticleHeliyon2022

Experimental investigation of air cooler using local palm tree waste.

Abdulmajeed Almaneea, Talal Awad Alshammari, Fahad Yousef Aldhafeeri, Muhammed Hamdan Aldhfeeri, Abdullah Abdulaziz Allaboun, Talal Sryan Almutairi

Open access · goldAbstract read
In one paragraph

Article in Heliyon, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 5 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Abdulmajeed AlmaneeaDepartment of Mechanical and Industrial Engineering, College of Engineering, Majmaah University, Al-Majmaah, 11952, Saudi Arabia.
Talal Awad AlshammariDepartment of Mechanical and Industrial Engineering, College of Engineering, Majmaah University, Al-Majmaah, 11952, Saudi Arabia.
Fahad Yousef AldhafeeriDepartment of Mechanical and Industrial Engineering, College of Engineering, Majmaah University, Al-Majmaah, 11952, Saudi Arabia.
Muhammed Hamdan AldhfeeriDepartment of Mechanical and Industrial Engineering, College of Engineering, Majmaah University, Al-Majmaah, 11952, Saudi Arabia.
Abdullah Abdulaziz AllabounDepartment of Mechanical and Industrial Engineering, College of Engineering, Majmaah University, Al-Majmaah, 11952, Saudi Arabia.
Talal Sryan AlmutairiDepartment of Mechanical and Industrial Engineering, College of Engineering, Majmaah University, Al-Majmaah, 11952, Saudi Arabia.
Majmaah University · SA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Middle Saudi Arabia has weather conditions where the temperature is high in summer with low humidity. Conventional air conditioning systems operated by a vapor compression cycle are not economical because of the high electrical power consumption. Therefore, evaporative cooling through evaporative coolers is one of the best and most economical solutions. The present study experimentally investigates the factors affecting the performance of evaporative coolers. Pad materials and airflow rate are the main variables to investigate the evaporative cooler's performance in terms of saturation effectiveness, pressure drop across the pads, and coefficient of performance (COP). Pads material are the local palm tree "Nakheel" waste that are leaflet, leaf base, bulb, and roots. The maximum COP of the cooling system in the case of bulb pad material is 80% more than that of leaflet pad material. The saturation effectiveness of the bulb pad was a maximum which is 61.93% at an airflow of 2.25 m/s, which is more than two times that of the saturation effectiveness of the leaflet pad. The pressure drop across the bulb pad is almost 2.5 times to 9.5 times than that of leaflet pad. Results show that bulb pad performance best, whereas the leaflet pad material has the lowest performance in terms of pressure drop, saturation effectiveness, and COP.

Indexed as

Air conditioning systemsAirflow rateEvaporative coolerPad materialsPressure dropSaturation effectiveness

Identifiers

PMID36072256
PMCPMC9441306
OpenAlexW4293671182

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.