Evidence map›Paper›PMID 36071495›Full record

ArticleBiomedical engineering online2022

Thermodiluted relative tidal volume estimation using a thermal camera in operating room under spinal anesthesia.

JunHwan Kwon, Oyun Kwon, KyeongTeak Oh, Jeongmin Kim, Cheung Soo Shin, Sun K Yoo

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05591469 (Respiratory Measurement Using Infrared Camera and Electrical Impedance Tomography for Sedation in Patients Undergoing TURP/TURB Under Spinal Anesthesia), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 57% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05591469 naunknown statusnot on this map

Respiratory Measurement Using Infrared Camera and Electrical Impedance Tomography for Sedation in Patients Undergoing TURP/TURB Under Spinal Anesthesia

TypeinterventionalSponsorYonsei UniversityRan2022 to 2023Enrolled20ConditionsPatients Undergoing Transurethral Prostate or Cystectomy Under Spinal AnesthesiaArmsIR Camera, Electrical Impedance Tomography
3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Breathing-Associated Facial Region Segmentation for Thermal Camera-Based Indirect Breathing Monitoring.IEEE journal of translational engineering in health and medicine · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

JunHwan KwonDepartment of Medical Engineering, Yonsei University College of Medicine, Seoul, Republic of Korea.
Oyun KwonDepartment of Medical Engineering, Yonsei University College of Medicine, Seoul, Republic of Korea.
KyeongTeak OhDepartment of Medical Engineering, Yonsei University College of Medicine, Seoul, Republic of Korea.
Jeongmin KimDepartment of Anesthesiology and Pain Medicine, Severance Hospital, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Cheung Soo ShinDepartment of Anesthesiology and Pain Medicine, Severance Hospital, Anesthesia and Pain Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea. CHEUNG56@yuhs.ac.
Sun K YooDepartment of Medical Engineering, Yonsei University College of Medicine, Seoul, Republic of Korea. SUNKYOO@yuhs.ac.
Yonsei University · KRSeverance Hospital · KR

Funding

Korea Medical Device Development Fund HW20C2151
6 · The paper itself

Abstract

backgroundEstimating relative tidal volume is an important factor when monitoring breathing status. The relationship between temperature and respiration volume has rarely been studied. In this paper, a formula was derived for calculating thermodiluted respiration volume from temperature changes in the nasal cavity. To evaluate the proposed formula, the study compared the relative tidal volume estimated by the proposed formula with that recorded by a respiration volume monitor (Exspiron1Xi, RVM). Thermal data were obtained for 8 cases at a rate of 10 measurements per second. Simultaneous recordings by the RVM are regarded as the reference.

resultsThe mean of ICC coefficient is 0.948 ± 0.030, RMSE is 0.1026 ± 0.0284, R-squared value is 0.8962 ± 0.065 and linear regression coefficient [Formula: see text] is 0.966 ± 0.104, [Formula: see text] is 0.042 ± 0.057. Bland-Altman plot showed 96.01% of samples that the difference between the measured and estimated values exists within 2 standard deviations.

conclusionsIn this paper, a model that can thermodynamically calculate the relationship between thermal energy and respiration volume is proposed. The thermodiluted model is a feasible method for estimating relative respiration tidal volumes.

Indexed as

Anesthesia, SpinalMonitoring, PhysiologicOperating RoomsRespirationTidal VolumeNon-contactRespirationThermal cameraTidal volume

Identifiers

PMID36071495
PMCPMC9450307
OpenAlexW4294991355

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.