ArticleJournal of medical Internet research2022
Newborn Skin Maturity Medical Device Validation for Gestational Age Prediction: Clinical Trial.
Article in Journal of medical Internet research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 4 citations in OpenAlex.
- Premature Infants With Pulmonary Complications Exhibit Decreased Skin Maturity Early After Birth: A Cross-Sectional Study.Pediatric pulmonology · 2026Article
- Assessment of Skin Maturity by LED Light at Birth and Its Association With Lung Maturity: Clinical Trial Secondary Outcomes.JMIR biomedical engineering · 2023Article
- Gestational age assessed by optical skin reflection in low-birth-weight newborns: Applications in classification at birth.Frontiers in pediatrics · 2023Article
- Respiratory distress syndrome prediction at birth by optical skin maturity assessment and machine learning models for limited-resource settings: a development and validation study.Frontiers in pediatrics · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
19 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundEarly access to antenatal care and high-cost technologies for pregnancy dating challenge early neonatal risk assessment at birth in resource-constrained settings. To overcome the absence or inaccuracy of postnatal gestational age (GA), we developed a new medical device to assess GA based on the photobiological properties of newborns' skin and predictive models.
objectiveThis study aims to validate a device that uses the photobiological model of skin maturity adjusted to the clinical data to detect GA and establish its accuracy in discriminating preterm newborns.
methodsA multicenter, single-blinded, and single-arm intention-to-diagnosis clinical trial evaluated the accuracy of a novel device for the detection of GA and preterm newborns. The first-trimester ultrasound, a second comparator ultrasound, and data regarding the last menstrual period (LMP) from antenatal reports were used as references for GA at birth. The new test for validation was performed using a portable multiband reflectance photometer device that assessed the skin maturity of newborns and used machine learning models to predict GA, adjusted for birth weight and antenatal corticosteroid therapy exposure.
resultsThe study group comprised 702 pregnant women who gave birth to 781 newborns, of which 366 (46.9%) were preterm newborns. As the primary outcome, the GA as predicted by the new test was in line with the reference GA that was calculated by using the intraclass correlation coefficient (0.969, 95% CI 0.964-0.973). The paired difference between predicted and reference GAs was -1.34 days, with Bland-Altman limits of -21.2 to 18.4 days. As a secondary outcome, the new test achieved 66.6% (95% CI 62.9%-70.1%) agreement with the reference GA within an error of 1 week. This agreement was similar to that of comparator-LMP-GAs (64.1%, 95% CI 60.7%-67.5%). The discrimination between preterm and term newborns via the device had a similar area under the receiver operating characteristic curve (0.970, 95% CI 0.959-0.981) compared with that for comparator-LMP-GAs (0.957, 95% CI 0.941-0.974). In newborns with absent or unreliable LMPs (n=451), the intent-to-discriminate analysis showed correct preterm versus term classifications with the new test, which achieved an accuracy of 89.6% (95% CI 86.4%-92.2%), while the accuracy for comparator-LMP-GA was 69.6% (95% CI 65.3%-73.7%).
conclusionsThe assessment of newborn's skin maturity (adjusted by learning models) promises accurate pregnancy dating at birth, even without the antenatal ultrasound reference. Thus, the novel device could add value to the set of clinical parameters that direct the delivery of neonatal care in birth scenarios where GA is unknown or unreliable. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR2-10.1136/bmjopen-2018-027442.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials