Evidence map›Paper›PMID 36069295›Full record

ArticleClinical and experimental dental research2022

Titanium implant surface roughness after different implantoplasty protocols: A laboratory study.

Hulya Yildiz, Kristina Bertl, Andreas Stavropoulos

Open access · goldAbstract read
In one paragraph

Article in Clinical and experimental dental research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 3 countries.

Hulya YildizDepartment of Periodontology, Faculty of Dentistry, Istanbul Aydın University, Istanbul, Turkey.ORCID 0000-0002-0847-8223
Kristina BertlDivision of Oral Surgery, University Clinic of Dentistry, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-8279-7943
Andreas StavropoulosDepartment of Periodontology, Faculty of Odontology, Univesity of Malmö, Malmö, Sweden.ORCID 0000-0001-8161-3754
Lund University · SEIstanbul Aydın University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the surface roughness of sandblasted, large grit, acid-etched (SLA) surfaced titanium discs, after implantoplasty (IP) with different combinations of rotating instruments without or with the subsequent use of a silicone polisher.

methodsTitanium discs (n = 12 per group) with an SLA surface were treated with the following IP protocols: (1) Tungsten carbide bur sequence from company 1 (Komet Dental) without or with polishing (P) with a silicone polisher (Brownie®), (2) tungsten carbide bur sequence from company 2 (Hager & Meisinger GmbH) without or with P, and (3) diamond bur sequence (125, 40, 15-μm grit) without or with P. Pristine turned (T) and SLA titanium discs were used as negative and positive controls, respectively. Surface roughness measurements were taken with a contact profilometer rendering R

resultsAll IP protocols, even without P, resulted in significantly reduced surface roughness compared to the SLA group. The tungsten carbide bur protocols, even without P, resulted in a surface roughness similar to or significantly lower than that in the T group in terms of R

conclusionsIP with dedicated tungsten carbide burs without or with the subsequent use of a silicone polisher resulted in a surface roughness similar to or significantly lower than that of commercially available turned surfaces. IP with a diamond bur sequence required additional polishing to achieve a comparable surface roughness to that of commercially available turned surfaces.

Indexed as

Dental ImplantsDental PolishingDiamondSiliconesSurface PropertiesTitaniumTungsten CompoundsDental ImplantsDiamondSiliconesTitaniumtungsten carbideTungsten Compoundsdiamond bursimplantoplastylaboratory studyprofilometersurface roughnesstungsten carbide burs

Identifiers

PMID36069295
PMCPMC9760168
OpenAlexW4294867749

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390