ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2023
Standardised aspiration first approach reduces materials used and cost of thrombectomy procedure in anterior circulation large vessel occlusion stoke.
Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 5 citations in OpenAlex.
- Stent retriever versus aspiration based thrombectomy: impact on first pass reperfusion, procedure time, and clinical outcomes in large vessel occlusion. Nationwide registry based cohort study.Journal of neurointerventional surgery · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe aim of this study is to compare the volume of equipment and equipment costs in a cohort of consecutive patients with anterior circulation large vessel occlusion treated with a standardised aspiration first approach to those treated with a stent retriever first approach.
methodsThe equipment used in each case was recorded from a prospectively maintained equipment log. We then compared the volume of equipment used in each group. The cost of this equipment was calculated for each group based on local prices. Estimated equipment costs were then compared.
resultsOur patient cohort consisted of 127 consecutive patients who were treated with a non-standardised stent retriever first technique (group A), 127 consecutive patients who underwent a new standardised aspiration first technique (group B), and 126 consecutive patients reflecting more recent practise where an aspiration first approach has been an established practise in our department (group C).Standardised aspiration first approach results in reduced equipment usage in thrombectomy procedures. The total equipment cost per case in the stent retriever first group (group A) was significantly higher at €4726.4 ($4818.3) versus €3093.1 ($3153.2) in the aspiration first group (group B), a reduction of 34.6% and €2798.5 ($2852.9) in the current practise group (group C), a reduction of 40.8%. There was no statistically significant difference in cost between groups B and C (p = 0.57).
conclusionThe standardised aspiration first technique utilised a reduced volume of equipment and confers a 40.8% reduced cost per procedure compared to a stent retriever first approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials