Evidence map›Paper›PMID 36066129›Full record

ArticleMedical physics2023

First experimental measurements of 2D microdosimetry maps in proton therapy.

Consuelo Guardiola, Diana Bachiller-Perea, Emmanuel M Mate Kole, Celeste Fleta, David Quirion, Ludovic De Marzi, Faustino Gómez

Open access · hybridAbstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.1field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 7 institutions in 2 countries.

Consuelo GuardiolaUniversité Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France.
Diana Bachiller-PereaUniversité Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France.
Emmanuel M Mate KoleUniversité Paris-Saclay, CNRS/IN2P3, IJCLab, Orsay, France.
Celeste FletaCentro Nacional de Microelectrónica (IMB-CNM, CSIC), Bellaterra, Spain.
David QuirionCentro Nacional de Microelectrónica (IMB-CNM, CSIC), Bellaterra, Spain.
Ludovic De MarziDepartment of Radiation Oncology, Institut Curie, PSL Research University, Centre de protonthérapie d'Orsay, Campus Universitaire, bâtiment 101, Orsay, France.
Faustino GómezDepartamento de Física de Partículas, Universidad de Santiago de Compostela, Santiago de Compostela, Spain.
Centre National de la Recherche Scientifique · FRCentro Nacional de Microelectrónica · ESInstitut Curie · FRInstitut de Microelectrònica de Barcelona · ESInstitut National de Physique Nucléaire et de Physique des Particules · FRUniversidade de Santiago de Compostela · ESUniversité Paris Cité · FR

Funding

European Union's Horizon 2020 Research and Innovation program 730983European Union's Horizon research and innovation program under the Marie Sklodowska-Curie 745109H2020 project AIDA-2020 654168
6 · The paper itself

Abstract

backgroundEmpirical data in proton therapy indicate that relative biological effectiveness (RBE) is not constant, and it is directly related to the linear energy transfer (LET). The experimental assessment of LET with high resolution would be a powerful tool for minimizing the LET hot spots in intensity-modulated proton therapy, RBE- or LET-guided evaluation and optimization to achieve biologically optimized proton plans, verifying the theoretical predictions of variable proton RBE models, and so on. This could impact clinical outcomes by reducing toxicities in organs at risk. PURPOSE: The present work shows the first 2D LET maps obtained at a proton therapy facility using the double scattering delivery mode in clinical conditions by means of new silicon 3D-cylindrical microdetectors.

methodsThe device consists of a matrix of 121 independent silicon-based detectors that have 3D-cylindrical electrodes of 25-µm diameter and 20-µm depth, resulting each one of them in a well-defined micrometric radiation sensitive volume etched inside the silicon. They have been specifically designed for a hadron therapy, improving the performance of current silicon-based microdosimeters. Microdosimetry spectra were obtained at different positions of the Bragg curve by using a water-equivalent phantom along an 89-MeV pristine proton beam generated in the Y1 proton passive scattering beamline of the Orsay Proton Therapy Centre (Institut Curie, France).

resultsMicrodosimetry 2D-maps showing the variation of the lineal energy with depth in the three dimensions were obtained in situ during irradiation at clinical fluence rates (∼10

conclusionsWe present the first 2D microdosimetry maps obtained in situ during irradiation at clinical fluence rates in proton therapy. Our results show that the arrays of 3D-cylindrical microdetectors are a reliable microdosimeter to evaluate LET maps not only in the longitudinal axis of the beam, but also in the transverse plane allowing for LET characterization in three dimensions. This work is a proof of principle showing the capacity of our system to deliver LET 2D maps. This kind of experimental data is needed to validate variable proton RBE models and to optimize LET-guided plans.

Indexed as

Proton TherapyMonte Carlo MethodProtonsRadiometryRelative Biological EffectivenessSiliconProtonsSiliconmicrodosimetryMonte Carlo simulationsproton therapyradiation sensorssilicon 3D-microdetectors

Identifiers

PMID36066129
PMCPMC10087596
OpenAlexW4294762721

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.