ArticleJournal of orthopaedic surgery and research2022
Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component.
Article in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it, 6 citations in OpenAlex.
- 3D imaging-based AI models outperform demographic models and excel in tibial sizing compared with 2D models in total knee arthroplasty planning: A systematic review.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Pooled it
- Precision medicine in orthopaedics: A review of current technologies and future directions.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2026Review
- Three-dimensional verification of osteotomy accuracy in total knee arthroplasty using intraoperative CT imaging: a case series study.BMC musculoskeletal disorders · 2025Article
- Accuracy of total knee arthroplasty using hospital-based 3D printed patient-specific instrumentation: A radiology research.Journal of orthopaedics · 2025Article
- Patient Specific Instruments and Patient Individual Implants-A Narrative Review.Journal of personalized medicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of this study was to evaluate the reproducibility of planned component positioning including tibial rotational alignment in patient-specific instrumentation (PSI) for total knee arthroplasty (TKA).
methodsA total of 100 knees of 100 patients underwent TKA using PSI (n = 50) or the conventional method (n = 50). Full-length anteroposterior radiographs of the lower limb were taken in the standing position, and the coronal alignments of the femoral and tibial components were measured. Computed tomography (CT) images of the lower limb were obtained preoperatively and postoperatively, and the rotational alignments of the femoral and tibial components were measured. The difference from the preoperative planning in tibial rotational alignment was measured using three-dimensionally merged pre- and postoperative images. The mean values and rates of outliers in each measurement were compared between the PSI group and the conventional group.
resultsThere were no significant differences in coronal alignment of the femoral and tibial components and rotational alignment of the femoral component between the two groups. With respect to rotational alignment of the tibial component from the preoperatively planned reference axis, the PSI group showed a lower rate of outliers (internal rotation > 10°) than the conventional group (p < 0.05).
conclusionsThis study demonstrated that the difference from the preoperative planning in tibial rotational positioning was accurately evaluated using novel three-dimensional measurement method, and PSI could reduce outliers in rotational alignment of the tibial component (internal rotation > 10°). PSI is a useful technique for improving the reproducibility of the planned tibial rotational positioning in TKA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials