Observational studyJournal of orthopaedic surgery and research2022
Can mobile-bearing unicompartmental knee arthroplasty achieve natural gap-balancing? An observational study with a novel pressure sensor.
Observational study in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Measured Resection as Gap Balance Method in Mobile-Bearing Medial Unicompartmental Knee Arthroplasty: A Randomized Controlled Trial.Orthopaedic surgery · 2025Trial
- Comparison of efficacy and cost-effectiveness between mobile-bearing and fixed-bearing unicompartmental knee arthroplasty for elderly patients with knee osteoarthritis: a retrospective cohort study.Frontiers in surgery · 2026Article
- From empirical to analytical: Soft-tissue tension gauging in total knee arthroplasty.Knee surgery & related research · 2025Review
- Robotic-assisted foot and ankle surgery: a review of the present status and the future.Biomedical engineering letters · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
backgroundMobile-bearing unicompartmental knee arthroplasty (MB-UKA) is an effective treatment for anteromedial knee osteoarthritis. Meticulous intraoperative soft tissue balancing remains challenging yet consequential for a successful operation. Currently, surgeons rely mostly on their experience during soft tissue balancing, yielding unreproducible results. The purpose of this study was to quantified measure the soft tissue tension of medial compartment and determine if an optimal "target" tension values with the natural state exists.
methodsThis was an observational study of 24 consecutive patients. All 30 UKAs were performed by a single surgeon. The piezoresistive sensor was custom designed to fit in the medial compartment gap. Contact pressures were measured at 5 angular positions of the knee intraoperatively: 0°, 20°, 45°, 90°, and 110° of flexion. The change in pressure from extension (20° position) and flexion (110° position) was also calculated (E-FPD). Data on age, sex, body mass index, operative side, and bearing size were collected. Outcome measures were measured at baseline and at the 6-month postoperative follow-up; Oxford Knee Score, visual analog scale score, and range of motion were compared to evaluate clinical outcomes.
resultsThere was a significant improvement in patients in all measured outcomes at 6 months from baseline (P < 0.05). The E-FPD of 14.9 N (8.9, 24.6) was indicative of appropriate soft tissue balancing throughout the functional range of knee motion. Of 30 knees, 22 were 3-mm bearing and 8 were 4- or 5-mm bearing. The pressure data of the 3-mm bearing group was larger than that of the non-3-mm bearing group for each knee flexion degree, but the difference was not statistically significant (P > 0.05).
conclusionsObjective data from sensor output may assist surgeons in decreasing loading variability during MB-UKA. The data suggested that MB-UKA could not accurately restore soft tissue tension to the natural state, which was related to the inability of MB-UKA surgical instruments to fine adjust the bone cut and soft tissue release. STUDY REGISTRATION: Chinese Clinical Trial Registry ( http://www.chictr.org.cn ): ChiCTR1900024146.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials