Evidence map›Paper›PMID 36064425›Full record

Observational studyJournal of orthopaedic surgery and research2022

Can mobile-bearing unicompartmental knee arthroplasty achieve natural gap-balancing? An observational study with a novel pressure sensor.

Shaokui Nan, Zheng Cao, Yue Song, Xiangpeng Kong, Haifeng Li, Wei Chai

Open access · goldAbstract readObservational Study
In one paragraph

Observational study in Journal of orthopaedic surgery and research, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 5 citations in OpenAlex.

  1. Trial
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Shaokui Nan *Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, China.
Zheng Cao *Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, China.
Yue Song *Senior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, China.
Xiangpeng KongSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, China.
Haifeng LiSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, China. lihaifengplagh@163.com.
Wei ChaiSenior Department of Orthopedics, The Fourth Medical Center of PLA General Hospital, No. 51 Fucheng Road, Beijing, 100048, China. chaiweiguanjie@sina.com.
Chinese PLA General Hospital · CN

Funding

Beijing Municipal Natural Science Foundation M22016
6 · The paper itself

Abstract

backgroundMobile-bearing unicompartmental knee arthroplasty (MB-UKA) is an effective treatment for anteromedial knee osteoarthritis. Meticulous intraoperative soft tissue balancing remains challenging yet consequential for a successful operation. Currently, surgeons rely mostly on their experience during soft tissue balancing, yielding unreproducible results. The purpose of this study was to quantified measure the soft tissue tension of medial compartment and determine if an optimal "target" tension values with the natural state exists.

methodsThis was an observational study of 24 consecutive patients. All 30 UKAs were performed by a single surgeon. The piezoresistive sensor was custom designed to fit in the medial compartment gap. Contact pressures were measured at 5 angular positions of the knee intraoperatively: 0°, 20°, 45°, 90°, and 110° of flexion. The change in pressure from extension (20° position) and flexion (110° position) was also calculated (E-FPD). Data on age, sex, body mass index, operative side, and bearing size were collected. Outcome measures were measured at baseline and at the 6-month postoperative follow-up; Oxford Knee Score, visual analog scale score, and range of motion were compared to evaluate clinical outcomes.

resultsThere was a significant improvement in patients in all measured outcomes at 6 months from baseline (P < 0.05). The E-FPD of 14.9 N (8.9, 24.6) was indicative of appropriate soft tissue balancing throughout the functional range of knee motion. Of 30 knees, 22 were 3-mm bearing and 8 were 4- or 5-mm bearing. The pressure data of the 3-mm bearing group was larger than that of the non-3-mm bearing group for each knee flexion degree, but the difference was not statistically significant (P > 0.05).

conclusionsObjective data from sensor output may assist surgeons in decreasing loading variability during MB-UKA. The data suggested that MB-UKA could not accurately restore soft tissue tension to the natural state, which was related to the inability of MB-UKA surgical instruments to fine adjust the bone cut and soft tissue release. STUDY REGISTRATION: Chinese Clinical Trial Registry ( http://www.chictr.org.cn ): ChiCTR1900024146.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeHumansKnee JointRange of Motion, ArticularClinical outcomesMobile bearingPressure sensorSoft tissue balancingUnicompartmental knee arthroplasty

Identifiers

PMID36064425
PMCPMC9446724
OpenAlexW4294647616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.