ArticleMagnetic resonance in medicine2023
Prospective motion correction in kidney MRI using FID navigators.
Article in Magnetic resonance in medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Respiratory Motion Management in Abdominal MRI: Revisiting the Gap Between Technical Advances and Clinical Translation.Magnetic resonance in medicine · 2026Review
- Pediatric functional kidney MRI: advancements, challenges, and the value of quantitative multiparametric imaging.Pediatric radiology · 2026Article
- Non-Subtractive Arterial Spin Labeling-Based (NSASL) Renal Magnetic Resonance Angiography (MRA): Development and Clinical Feasibility Evaluation.Journal of magnetic resonance imaging : JMRI · 2026Article
- Investigation of Endogenous Renal CEST Contrast and the Influence of Respiratory Motion on a Clinical 3 Tesla MRI: An In Vivo and In Vitro Study.Magnetic resonance in medicine · 2026Article
- Motion Mitigation Techniques for Abdominal and Cardiac MR Imaging.Journal of magnetic resonance imaging : JMRI · 2026Review
- Motion and Flow Robust Free-Breathing Diffusion Kurtosis Imaging of the Kidney.NMR in biomedicine · 2025Article
- Ultrafast and robustMagnetic resonance in medicine · 2025Article
- A Multi-view Open-access Dataset of Paired Knee MRI for Motion Artifact Removal.Scientific data · 2025Article
- Distortionless, free-breathing, and respiratory resolved 3D diffusion weighted imaging of the abdomen.Magnetic resonance in medicine · 2024Article
- Motion-compensated image reconstruction for improved kidney function assessment using dynamic contrast-enhanced MRI.NMR in biomedicine · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
purposeAbdominal MRI scans may require breath-holding to prevent image quality degradation, which can be challenging for patients, especially children. In this study, we evaluate whether FID navigators can be used to measure and correct for motion prospectively, in real-time.
methodsFID navigators were inserted into a 3D radial sequence with stack-of-stars sampling. MRI experiments were conducted on 6 healthy volunteers. A calibration scan was first acquired to create a linear motion model that estimates the kidney displacement due to respiration from the FID navigator signal. This model was then applied to predict and prospectively correct for motion in real time during deep and continuous deep breathing scans. Resultant images acquired with the proposed technique were compared with those acquired without motion correction. Dice scores were calculated between inhale/exhale motion states. Furthermore, images acquired using the proposed technique were compared with images from extra-dimensional golden-angle radial sparse parallel, a retrospective motion state binning technique.
resultsImages reconstructed for each motion state show that the kidneys' position could be accurately tracked and corrected with the proposed method. The mean of Dice scores computed between the motion states were improved from 0.93 to 0.96 using the proposed technique. Depiction of the kidneys was improved in the combined images of all motion states. Comparing results of the proposed technique and extra-dimensional golden-angle radial sparse parallel, high-quality images can be reconstructed from a fraction of spokes using the proposed method.
conclusionThe proposed technique reduces blurriness and motion artifacts in kidney imaging by prospectively correcting their position both in-plane and through-slice.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.