Stair Ascent Phase-Variable Control of a Powered Knee-Ankle Prosthesis.
Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- The Only Way Is Up: Active Knee Exoskeleton Reduces Muscular Effort in Quadriceps During Weighted Stair Ascent.IEEE robotics and automation letters · 2025Article
- Automatic Stub Avoidance for a Powered Prosthetic Leg Over Stairs and Obstacles.IEEE transactions on bio-medical engineering · 2024Article
- Data-Driven Phase-Based Control of a Powered Knee-Ankle Prosthesis for Variable-Incline Stair Ascent and Descent.IEEE transactions on medical robotics and bionics · 2024Article
- Controlling Powered Prosthesis Kinematics over Continuous Transitions Between Walk and Stair Ascent.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2023Article
- Design, Kinematics and Gait Analysis, of Prosthetic Knee Joints: A Systematic Review.Bioengineering (Basel, Switzerland) · 2023Review
- Data-Driven Variable Impedance Control of a Powered Knee-Ankle Prosthesis for Adaptive Speed and Incline Walking.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2023Article
- Modeling the Transitional Kinematics Between Variable-Incline Walking and Stair Climbing.IEEE transactions on medical robotics and bionics · 2022Article
- Gait Event Detection with Proprioceptive Force Sensing in a Powered Knee-Ankle Prosthesis: Validation over Walking Speeds and Slopes.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and AutomationArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Passive prostheses cannot provide the net positive work required at the knee and ankle for step-over stair ascent. Powered prostheses can provide this net positive work, but user synchronization of joint motion and power input are critical to enabling natural stair ascent gaits. In this work, we build on previous phase variable-based control methods for walking and propose a stair ascent controller driven by the motion of the user's residual thigh. We use reference kinematics from an able-bodied dataset to produce knee and ankle joint trajectories parameterized by gait phase. We redefine the gait cycle to begin at the point of maximum hip flexion instead of heel strike to improve the phase estimate. Able-bodied bypass adapter experiments demonstrate that the phase variable controller replicates normative able-bodied kinematic trajectories with a root mean squared error of 12.66° and 2.64° for the knee and ankle, respectively. The knee and ankle joints provided on average 0.39 J/kg and 0.21 J/kg per stride, compared to the normative averages of 0.34 J/kg and 0.21 J/kg, respectively. Thus, this controller allows powered knee-ankle prostheses to perform net positive mechanical work to assist stair ascent.
Identifiers
What OpenQuestion holds
Registered trials