Evidence map›Paper›PMID 36060597›Full record

ArticleQuantitative imaging in medicine and surgery2022

The feasibility of superparamagnetic iron oxide-enhanced magnetic resonance imaging for assessing liver lesions in patients with contraindications for iodine CT contrast media or gadolinium-based MR contrast media: a retrospective case-control study.

Chishio Kurata, Kazuhiro Saito, Natsuhiko Shirota, Yoichi Araki, Katsutoshi Sugimoto, Yu Tajima, Daisuke Yunaiyama

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chishio KurataDepartment of Radiology, Tokyo Medical University, Tokyo, Japan.
Kazuhiro SaitoDepartment of Radiology, Tokyo Medical University, Tokyo, Japan.
Natsuhiko ShirotaDepartment of Radiology, Tokyo Medical University, Tokyo, Japan.
Yoichi ArakiDepartment of Radiology, Tokyo Medical University, Tokyo, Japan.
Katsutoshi SugimotoDepartment of Gastroenterology and Hepatology, Tokyo Medical University, Tokyo, Japan.
Yu TajimaDepartment of Radiology, Tokyo Medical University, Tokyo, Japan.
Daisuke YunaiyamaDepartment of Radiology, Tokyo Medical University, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The detection and characterization of liver lesions are problematic in patients with bronchial asthma, renal dysfunction, or a history of allergy to gadolinium-based magnetic resonance contrast media or iodine-computed tomography contrast media because these contrast media cannot be used. Hence, the information on the lesion vascularity cannot be obtained. Therefore, this retrospective case-control study evaluated the feasibility of superparamagnetic iron oxide (SPIO) in patients with one or more of these contraindications who underwent SPIO-enhanced magnetic resonance imaging for the assessment of liver lesions. Methods: Twenty-six patients with a total of 48 lesions were analyzed. SPIO was used in the case of all patients because each patient had at least one reason not to use iodine contrast or gadolinium-based contrast media. Additionally, all patients were subjected to the perfusion study. A total volume of 1.3 mL of SPIO was injected via the cubital vein at a rate of 3 mL per second, followed by 40 mL saline at the same speed. The scanning of the perfusion study was started 4 s after the beginning of superparamagnetic iron oxide injection and scanning took 50 s. Two radiologists independently evaluated whether the lesion was malignant or benign. Receiver operating characteristic analysis (ROC) was performed to determine the additional benefit of the perfusion study. Results: There were no adverse effects associated with SPIO. The area under the curve (AUC) value without perfusion study for observers 1 and 2 were 0.473 (P=0.794, 95% CI: 0.275-0.672) and 0.602 (P=0.305, 95% CI: 0.407-0.798), respectively, whereas the Az values with perfusion study for observers 1 and 2 were 0.782 (P=0.011, 95% CI: 0.565-0.998) and 0.784 (P=0.004, 95% CI: 0.591-0.977), respectively. Az value became significantly better when the perfusion study has added (P=0.001 and 0.012 by observers 1 and 2). Conclusions: SPIO can be used safely in patients with bronchial asthma, renal dysfunction, or a history of contrast media allergy. Furthermore, the diagnostic accuracy of SPIO was acceptable.

Indexed as

asthmahepatocellular carcinomalesion vascularityrenal dysfunctionSuperparamagnetic iron oxide (SPIO)

Identifiers

PMID36060597
PMCPMC9403591

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.