Evidence map›Paper›PMID 36060581›Full record

ArticleQuantitative imaging in medicine and surgery2022

Ultra-low dose CT for scaphoid fracture detection-a simulational approach to quantify the capability of radiation exposure reduction without diagnostic limitation.

Gabriel Keller, Florian Hagen, Leoni Neubauer, Katarzyna Rachunek, Fabian Springer, Mareen Sarah Kraus

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Gabriel KellerDepartment of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany.
Florian HagenDepartment of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany.
Leoni NeubauerDepartment of Radiation Protection, University Hospital Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany.
Katarzyna RachunekDepartment of Hand, Plastic, Reconstructive and Burn Surgery, BG Trauma Center Tübingen, Eberhard Karls University of Tübingen, Tübingen, Germany.
Fabian SpringerDepartment of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany.
Mareen Sarah KrausDepartment of Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Modern CT might deliver higher image quality than necessary for fracture imaging, which would mean non-essential effective radiation exposure for patients. We simulated ultra-low dose (ULD)-CT at different dose levels and analyzed their diagnostic performance for scaphoid fracture detection. Methods: 30 consecutive high quality CT with clinically suspected scaphoid fractures were assessed. ULD-simulations were made at 20%, 10% and 5% of original dose. Three readers at different levels of experience (expert, moderate, inexperienced) expressed their diagnostic confidence (DC; 5-point-Likert-scale) and analyzed the presence and classification of scaphoid fractures within Krimmer's and Herbert's classifications. Effective radiation exposure of the original data sets and ULD-CT were calculated. Results: At 20% and 10% dose the more experienced readers reached perfect sensitivity (100%) and specificity (100%), showing perfect agreement regarding fracture classification (1.00). Diagnostic performance decreased at 5% dose (92.86% sensitivity, 100% specificity; expert reader). The inexperienced reader showed reduced sensitivity and specificity at all dose levels. At 10% dose minimal DC of all readers was 3/5 and mean calculated effective radiation exposure was 1.11 [±0.36] µSv. Conclusions: The results suggest that ULD-CT at 10% dose compared to high quality CT might offer sufficient image quality to precisely detect and classify scaphoid fractures, if moderate experience of the radiologist is granted.

Indexed as

computed tomographyradiation dosagereader experienceScaphoid fractureultra-low dose (ULD)