Evidence map›Paper›PMID 36059076›Full record

ArticleJournal of biomedical optics2022

Non-invasive blood glucose sensing by machine learning of optic fiber-based speckle pattern variation.

Deep Pal, Sergey Agadarov, Yevgeny Beiderman, Yafim Beiderman, Amitesh Kumar, Zeev Zalevsky

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
4.5field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Deep PalBar-Ilan University, Faculty of Engineering, Ramat Gan, Israel, Israel.
Sergey AgadarovBar-Ilan University, Faculty of Engineering, Ramat Gan, Israel, Israel.
Yevgeny BeidermanHolon Institute of Technology (HIT), Faculty of Electrical Engineering, Holon, Israel
Yafim BeidermanBar-Ilan University, Faculty of Engineering, Ramat Gan, Israel, Israel.
Amitesh KumarIndian Institute of Technology (Indian School of Mines) Dhanbad, Department of Electronics Engineering, Dhanbad, Jharkhand, India, India.
Zeev ZalevskyBar-Ilan University, Faculty of Engineering, Ramat Gan, Israel, Israel.
Bar-Ilan University · ILHolon Institute of Technology · ILIndian Institute of Technology Dhanbad · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceThe ability to perform frequent non-invasive monitoring of glucose in the bloodstream is very applicable for diabetic patients.

aimWe experimentally verified a non-invasive multimode fiber-based technique for sensing glucose concentration in the bloodstream by extracting and analyzing the collected speckle patterns. APPROACH: The proposed sensor consists of a laser source, digital camera, computer, multimode fiber, and alternating current (AC) generated magnetic field source. The experiments were performed using a covered (with cladding and jacket) and uncovered (without cladding and jacket) multimode fiber touching the skin under a magnetic field and without it. The subject's finger was placed on a fiber to detect the glucose concentration. The method tracks variations in the speckle patterns due to light interaction with the bloodstream affected by blood glucose.

resultsThe uncovered fiber placed above the finger under the AC magnetic field (150 G) at 140 Hz was found to have a lock-in amplification role, improving the glucose detection precision. The application of the machine learning algorithms in preprocessed speckle pattern data increase glucose measurement accuracy. Classification of the speckle patterns for uncovered fiber under the AC magnetic field allowed for detection of the blood glucose with high accuracy for all tested subjects compared with other tested configurations.

conclusionsThe proposed technique was theoretically analyzed and experimentally validated in this work. The results were verified by the traditional finger-prick method, which was also used for classification as a conventional reference marker of blood glucose levels. The main goal of the proposed technique was to develop a non-invasive, low-cost blood glucose sensor for easy use by humans.

Indexed as

Blood GlucoseFiber Optic TechnologyAlgorithmsHumansLasersMachine LearningBlood Glucoseclassificationglucose sensorlasersmachine learningmagneto-opticsnon-invasiveoptical fiber sensorsoptics

Identifiers

PMID36059076
PMCPMC9441213
OpenAlexW4294562616

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.