Evidence map›Paper›PMID 36058933›Full record

ArticleBMC cardiovascular disorders2022

Minimally invasive apical cannulation and cannula design for short-term mechanical circulatory support devices.

Marcell Székely, Tamás Ruttkay, Ferenc Imre Suhai, Áron Bóna, Béla Merkely, László Székely

Open access · goldAbstract read
In one paragraph

Article in BMC cardiovascular disorders, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 64% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Minimally invasive, transapical dual-lumened cannula for short-term left ventricular support in a clinically relevant large animal model†.European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Marcell SzékelyLaboratory for Applied and Clinical Anatomy, Department of Anatomy, Histology, and Embryology, Semmelweis University, 58 Tűzoltó Street, Budapest, 1094, Hungary. marcellszekely98@gmail.com.ORCID 0000-0002-3108-5065
Tamás RuttkayLaboratory for Applied and Clinical Anatomy, Department of Anatomy, Histology, and Embryology, Semmelweis University, 58 Tűzoltó Street, Budapest, 1094, Hungary.
Ferenc Imre SuhaiHeart and Vascular Center, Semmelweis University, 68 Városmajor Road, Budapest, 1122, Hungary.
Áron BónaSoós Research and Development Center, University of Pannonia, 18 Zrínyi Miklós Street, Nagykanizsa, 8800, Hungary.
Béla MerkelyHeart and Vascular Center, Semmelweis University, 68 Városmajor Road, Budapest, 1122, Hungary.
László SzékelyMilitary Hospital Medical Centre, Cardiovascular and Thoracic Surgery Department, Hungarian Defense Forces, 44 Róbert Károly Boulevard, Budapest, 1134, Hungary.
Semmelweis University · HUUniversity of Pannonia · HU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRefractory cardiogenic shock is still a major clinical challenge with high mortality rates, although several devices can be used to conquer this event. These devices have different advantages and disadvantages originating from their insertion or cannulation method, therefore many complications can occur during their use. The aim of our study was to develop and create prototypes of a novel minimal invasively insertable, transapical cannula for surgical ventricular assist devices, which uniquely incorporates the inflow and outflow routes for the blood of the patient in itself, therefore it enables the use for only one cannula for patients in cardiogenic shock.

methodsTo define the available space for the planned cannula in the left ventricle and ascending aorta, we analyzed computed tomography scans of 24 heart failure patients, who were indicated to left ventricular assist device therapy. Parallel to these measurements, hydrodynamical calculations were performed to determine the sizes of the cannulas, which were necessary to provide effective cardiac output.

resultsAfter the designing steps, we produced prototypes of double-lumened, tube-in-tube apically insertable devices for three different patient groups, which included a separated venous and an arterial part using 3D modelling and printing technology. All the created cannulas are able to provide 5 l/min circulatory support.

conclusionAs a result of our research we created a sizing method based on the specific analysis of computed tomography pictures of end stage heart failure patients and a cannula concept, which can provide effective antegrade flow for patients in cardiogenic shock. We believe the improved version of our tool could have a significant therapeutic role in the future after further development based on animal and in vivo tests.

Indexed as

Heart-Assist DevicesHeart FailureAnimalsCannulaCardiac CatheterizationShock, CardiogenicCardiogenic shockHeart failureLeft ventricular assist device

Identifiers

PMID36058933
PMCPMC9441023
OpenAlexW4294668174

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.