Evidence map›Paper›PMID 36057935›Full record

ArticleRapid communications in mass spectrometry : RCM2022

Improved spatial resolution of infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging using a reflective objective.

Alena N Joignant, Hongxia Bai, Jeffrey G Manni, David C Muddiman

Abstract read
In one paragraph

Article in Rapid communications in mass spectrometry : RCM, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Oversampling for Enhanced Spatial Resolution of Zebrafish by Top-Hat IR-MALDESI-MSI.Journal of the American Society for Mass Spectrometry · 2024
    Article
  8. Prototyping an ionization source for non-engineers.Journal of mass spectrometry : JMS · 2024
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Alena N JoignantFTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA.
Hongxia BaiFTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA.
Jeffrey G ManniJGM Associates Inc, Burlington, MA, USA.
David C MuddimanFTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, NC, USA.ORCID https://orcid.org/0000-0003-2216-499X

Funding

Development and Application of New Ionization Methods for Biological Mass SpectrometryR01GM087964 · NIGMS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI MUDDIMAN, DAVID C. · 2010 to 2025
$4.7M
NC STATE MOLECULAR BIOTECHNOLOGY TRAINING PROGRAM (MBTP)T32GM133366 · NIGMS · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI Jason M. Haugh, Robert M Kelly · 2020 to 2026
$3.3M
National Institute of Health R01GM087964NIGMS NIH HHS R01 GM087964NIGMS NIH HHS T32 GM133366NIH/NCSU Molecular Biotechnology Training Program 5T32GM133366-03
6 · The paper itself

Abstract

rationaleThe level of visual detail of a mass spectrometry image is dependent on the spatial resolution with which it is acquired, which is largely determined by the focal diameter in infrared laser ablation-based techniques. While the use of mid-IR light for mass spectrometry imaging (MSI) has advantages, it results in a relatively large focal diameter and spatial resolution. The continual advancement of infrared matrix-assisted electrospray ionization (IR-MALDESI) for MSI warranted novel methods to decrease laser ablation areas and thus improve spatial resolution.

methodsIn this work, a Schwarzschild-like reflective objective was incorporated into the novel NextGen IR-MALDESI source and characterized on both burn paper and mammalian tissue using an ice matrix. Ablation areas, mass spectra, and annotations obtained using the objective were compared against the current optical train on the NextGen system without modification.

resultsThe effective resolution was determined to be 55 μm by decreasing the step size until oversampling was observed. Use of the objective improved the spatial resolution by a factor of three as compared against the focus lens.

conclusionsA Schwarzschild-like reflective objective was successfully incorporated into the NextGen source and characterized on mammalian tissue using an ice matrix. The corresponding improvement in spatial resolution facilitates the future expansion of IR-MALDESI applications to include those that require fine structural detail.

Indexed as

IceSpectrometry, Mass, Electrospray IonizationAnimalsLasersMammalsSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationIce

Identifiers

PMID36057935
PMCPMC9643617

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.