ArticleItalian journal of pediatrics2022
Clinical analysis of bronchoscope diagnosis and treatment for airway foreign body removal in pediatric patients.
Article in Italian journal of pediatrics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 23 citations in OpenAlex.
- Rigid bronchoscopy is the gold standard management of inhaled foreign bodies in children: myth or maxim?Breathe (Sheffield, England) · 2026Review
- Prediction and diagnosis of suspected foreign body aspiration in children using flexible bronchoscopy: a retrospective cohort study.European journal of pediatrics · 2025Article
- Cryotherapy via Flexible Bronchoscopy for Pediatric Plastic Bronchitis: A Case Report.The American journal of case reports · 2025Article
- Decoding airway granulogenesis in children: unveiling risk factors for tracheobronchial foreign body aspiration and complications.Italian journal of pediatrics · 2025Article
- Clinical application of flexible fiberoptic bronchoscopy in neonatal respiratory diseases.Italian journal of pediatrics · 2024Article
- Progress in the Application of Bronchoscopic Cryotherapy in Pediatric Pulmonary Diseases.Children (Basel, Switzerland) · 2024Review
- Hypoxaemia risk in pediatric flexible bronchoscopy for foreign body removal: a retrospective study.BMC pediatrics · 2024Article
- Rigid bronchoscopy: a consultant survey.Annals of the Royal College of Surgeons of England · 2024Article
- The global, regional, and national burden of foreign bodies from 1990 to 2019: a systematic analysis of the global burden of disease study 2019.BMC public health · 2024Article
- An unusual presentation of necrotizing pneumonia caused by foreign body retention in a 20-month-old child: A case report and literature review.Frontiers in pediatrics · 2023Article
- Management of Accidental Aspiration of a Broken Luer Slip Needle during Intraoral Irrigation - A Case Report.Annals of maxillofacial surgeryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAlong with the wide spread application and technical development of the flexible and rigid bronchoscopy, the airway foreign body removing method cme to the specific technique for different foreign bodies from the single foreign body forceps.
methodsSelected 633 children who were diagnosed as airway foreign bodies by the Department of Respiratory Intervention, Children's Hospital affiliated to Shandong University from January 1st, 2018 to December 31st, 2021, and the airway foreign bodies were diagnosed using bronchoscopy. After comprehensive assessment of the foreign body nature in the airway, the foreign bodies were removed by freezing, laser, electrocoagulation, balloon and other techniques, the success rate of the foreign body removed from the airway was observed, the percentage of the foreign body removed using different techniques, the operation time, and the incidence of post-adverse reactions during operation.
resultsThe success rate using flexible bronchoscope alone to remove foreign bodies in the airway was 99.2%. After flexible bronchoscopy, 19 cases of foreign bodies were removed by vacuum suction alone, 513 cases were removed by foreign body forceps alone, 62 cases were combined with cryotherapy, 2 cases were electrocoagulation, 6 cases were mesh baskets, 3 cases were balloons, 5 cases were laser, and various 18 cases of foreign bodies were invloved by technical combination. 5 cases of flexible bronchoscope combined with rigid bronchoscope combined to remove foreign bodies. The operation time was from 5 min to 1 h, with an average of 20 min. There were 17 cases of hypoxemia (2.7%) during operation, 36 cases (5.7%) of bleeding caused by airway mucosa injury after treatment, and 70 cases (11.2%) of laryngeal edema. The total incidence of adverse reactions was 19.6%, there were no deaths due to foreign bodies and treatment.
conclusionsAccording to different properties of airway foreign bodies, it is safe and effective to select appropriate techniques to remove foreign bodies using the flexible bronchoscope, which can increase the removal rate of airway foreign bodies and reduce the occurrence of serious complications.
Indexed as