ArticlePloS one2022
A model for designing intraocular pressure-regulating glaucoma implants.
Article in PloS one, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 7 citations in OpenAlex.
- Immunomodulatory topographies regulate myofibroblast differentiation and influence fibrous encapsulation of glaucoma drainage devices.Bioactive materials · 2026Article
- Long-Term Intraocular Pressure-Lowering and Antifibrotic Effects of a Biodegradable HA-Mg Glaucoma Drainage Implant in a Chronic Glaucoma Rabbit Model.Translational vision science & technology · 2026Article
- Trabecular Meshwork-Based MIGS: Efficacy, Technique Variability, and Wound Healing-A Comprehensive Review.Journal of clinical medicine · 2026Review
- Angular threshold for intraocular pressure elevation during robot-assisted radical prostatectomy in Trendelenburg position.Frontiers in medicine · 2026Article
- Intraluminal 10-0 Nylon Stenting in PRESERFLO™ MicroShunt Surgery for Pseudoexfoliation Glaucoma.Journal of clinical medicine · 2025Article
- Systematic Preserflo MicroShunt Intraluminal Stenting for Hypotony Prevention in Highly Myopic Patients: A Comparative Study.Journal of clinical medicine · 2023Article
- Magnetically actuated glaucoma drainage device for regulating intraocular pressure after implantation.Microsystems & nanoengineering · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Glaucoma is a group of eye conditions that damage the optic nerve, the health of which is vital for vision. The key risk factor for the development and progression of this disease is increased intraocular pressure (IOP). Implantable glaucoma drainage devices have been developed to divert aqueous humor from the glaucomatous eye as a means of reducing IOP. The artificial drainage pathway created by these devices drives the fluid into a filtering bleb. The long-term success of filtration surgery is dictated by the proper functioning of the bleb and overlying Tenon's and conjunctival tissue. To better understand the influence of the health condition of these tissues on IOP, we have developed a mathematical model of fluid production in the eye, its removal from the anterior chamber by a particular glaucoma implant-the PRESERFLO® MicroShunt-, drainage into the bleb and absorption by the subconjunctival vasculature. The mathematical model was numerically solved by commercial FEM package COMSOL. Our numerical results of IOP for different postoperative conditions are consistent with the available evidence on IOP outcomes after the implantation of this device. To obtain insight into the adjustments in the implant's hydrodynamic resistance that are required for IOP control when hypotony or bleb scarring due to tissue fibrosis take place, we have simulated the flow through a microshunt with an adjustable lumen diameter. Our findings show that increasing the hydrodynamic resistance of the microshunt by reducing the lumen diameter, can effectively help to prevent hypotony. However, decreasing the hydrodynamic resistance of the implant will not sufficiently decrease the IOP to acceptable levels when the bleb is encapsulated due to tissue fibrosis. Therefore, to effectively reduce IOP, the adjustable glaucoma implant should be combined with a means of reducing fibrosis. The results reported herein may provide guidelines to support the design of future glaucoma implants with adjustable hydrodynamic resistances.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.