Evidence map›Paper›PMID 36052983›Full record

ArticleJournal of applied clinical medical physics2022

Comparison of anatomically informed class solution template trajectories with patient-specific trajectories for stereotactic radiosurgery and radiotherapy.

John David Lincoln, Robert Lee MacDonald, Brian Little, Alasdair Syme, Christopher Grant Thomas

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

John David LincolnDepartment of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.
Robert Lee MacDonaldDepartment of Medical Physics, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
Brian LittleDepartment of Medical Physics, Nova Scotia Health Authority, Halifax, Nova Scotia, Canada.
Alasdair SymeDepartment of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.
Christopher Grant ThomasDepartment of Physics and Atmospheric Science, Dalhousie University, Halifax, Nova Scotia, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Class solution template trajectories are used clinically for efficiency, safety, and reproducibility. The aim was to develop class solutions for single cranial metastases radiotherapy/radiosurgery based on intracranial target positioning and compare to patient-specific trajectories in the context of 4π optimization. Template trajectories were constructed based on the open-source Montreal Neurological Institute (MNI) average brain. The MNI brain was populated with evenly spaced spherical target volumes (2 cm diameter, N = 243) and organs-at-risk (OARs) were identified. Template trajectories were generated for six anatomical regions (frontal, medial, and posterior, each with laterality dependence) based on previously published 4π optimization methods. Volumetric modulated arc therapy (VMAT) treatment plans generated using anatomically informed template 4π trajectories and patientspecific 4π trajectories were compared against VMAT plans from a standard four-arc template. Four-arc optimization techniques were compared to the standard VMAT template by placing three spherical targets in each of six anatomical regions of a test patient. This yielded 54 plans to compare various plan quality metrics. Increasing plan technique complexity, the total number of OAR maximum dose reductions compared to the standard arc template for the 6 anatomical classes was 4+/-2 (OFIXEDc) and 7+/-2 (OFIXEDi). In 65.6% of all cases, optimized fixed-couch positions outperformed the standard-arc template. Of the three comparisons, the most complex (OFIXEDi) showed the greatest statistical significance compared to the least complex (VMATi) across 12 plan quality metrics of maximum dose to each OAR, V12Gy, total plan Monitor Units, conformity index, and gradient index (p < 0.00417). In approximately 70% of all cases, 4π optimization methods outperformed the standard-arc template in terms of maximum dose reduction to OAR, by exclusively changing the arc geometry. We conclude that a tradeoff exists between complexity of a class solution methodology compared to patient-specific methods for arc selection, in the context of plan quality improvement.

Indexed as

RadiosurgeryRadiotherapy, Intensity-ModulatedHumansRadiotherapy DosageRadiotherapy Planning, Computer-AssistedReproducibility of Results4piautomationnoncoplanaroptimizationSRS/SRTtrajectory optimization

Identifiers

PMID36052983
PMCPMC9680573

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.