Dual-wavelength photoacoustic atlas method to estimate fractional methylene blue and hemoglobin contents.

Eduardo Gonzalez, Muyinatu Lediju Bell

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical optics, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 46% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 5 citations in OpenAlex.

  1. Review
  2. Article
  3. Deep Learning to Localize Photoacoustic Sources in Three Dimensions: Theory and Implementation.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2025
    Article
  4. Article
  5. Article
  6. Optical absorption spectra and correspondingJournal of biomedical optics · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Eduardo GonzalezJohns Hopkins Univ., United States.
Muyinatu Lediju BellJohns Hopkins Univ., United States.
Johns Hopkins Medicine · US

Funding

Coherence-Based Photoacoustic Image Guidance of Transsphenoidal SurgeriesR00EB018994 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI BELL, MUYINATU A. LEDIJU · 2017 to 2019
$726k
NIBIB NIH HHS R00 EB018994
6 · The paper itself

Abstract

significanceMethylene blue (MB) is an exogenous contrast agent that has the potential to assist with visualization and penetration challenges in photoacoustic imaging. However, monitoring the local concentration between MB and endogenous chromophores is critical for avoiding unnecessary MB accumulations that could lead to adverse effects such as hemolysis when exposed to increased dose and photodamage when exposed to high laser energies.

aimWe developed a modified version of a previously proposed acoustic-based atlas method to estimate concentration levels from a mixture of two photoacoustic-sensitive materials after two laser wavelength emissions. APPROACH: Photoacoustic data were acquired from mixtures of 100-μM MB and either human or porcine blood (Hb) injected in a plastisol phantom, using laser wavelengths of 710 and 870 nm. An algorithm to perform linear regression of the acoustic frequency response from an atlas composed of pure concentrations was designed to assess the concentration levels from photoacoustic samples obtained from 11 known MB/Hb volume mixtures. The mean absolute error (MAE), coefficient of determination (i.e., R2), and Spearman's correlation coefficient (i.e., ρ) between the estimated results and ground-truth labels were calculated to assess the algorithm performance, linearity, and monotonicity, respectively.

resultsThe overall MAE, R2, and ρ were 12.68%, 0.80, and 0.89, respectively, for the human Hb dataset and 9.92%, 0.86, and 0.93, respectively, for the porcine Hb dataset. In addition, a similarly linear relationship was observed between the acoustic frequency response at 2.3 MHz and 870-nm laser wavelength and the ground-truth concentrations, with R2 and | ρ | values of 0.76 and 0.88, respectively.

conclusionsContrast agent concentration monitoring is feasible with the proposed approach. The potential for minimal data acquisition times with only two wavelength emissions is advantageous toward real-time implementation in the operating room.

Indexed as

Photoacoustic TechniquesAnimalsContrast MediaHemoglobinsHumansMethylene BluePhantoms, ImagingSwineContrast MediaHemoglobinsMethylene Bluecoherence-based beamformingcontrast agentmonitoringphotoacousticprincipal component analysis

Identifiers

PMID36050818
PMCPMC9433893
OpenAlexW4294307556

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.