Evidence map›Paper›PMID 36050445›Full record

ArticleScientific reports2022

Swept-source OCT for corneal graft quantitative evaluation in the eye bank and the correlation of the measurements to pre-excision values.

Bartlomiej J Kaluzny, Patryk Mlyniuk, Slawomir Liberski, Alfonso Jimenez-Villar, Anna Machalińska, Ireneusz Grulkowski

Open access · goldAbstract read
In one paragraph

Article in Scientific reports, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 84% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Bartlomiej J KaluznyDivision of Ophthalmology and Optometry, Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, Ul. K. Ujejskiego 75, 85-168, Bydgoszcz, Poland.
Patryk MlyniukDivision of Ophthalmology and Optometry, Department of Ophthalmology, Collegium Medicum, Nicolaus Copernicus University, Ul. K. Ujejskiego 75, 85-168, Bydgoszcz, Poland.
Slawomir LiberskiDepartment of Ophthalmology, Poznan University of Medical Sciences, Ul. A. Szamarzewskiego 84, 61-848, Poznań, Poland. liberski.slawomir@gmail.com.
Alfonso Jimenez-VillarInstitute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Ul. Grudziądzka 5, 87-100, Toruń, Poland.
Anna MachalińskaFirst Department of Ophthalmology, Pomeranian Medical University, Al. Powstańców Wielkopolskich 72, 70-111, Szczecin, Poland.
Ireneusz GrulkowskiInstitute of Physics, Faculty of Physics, Astronomy and Informatics, Nicolaus Copernicus University, Ul. Grudziądzka 5, 87-100, Toruń, Poland.
Nicolaus Copernicus University · PLPomeranian Medical University · PLPoznan University of Medical Sciences · PLUniversity of Bydgoszcz · PL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Quantitative evaluation of the human corneal grafts stored in the tissue banks is usually limited to endothelial cell density and central thickness. Swept-source OCT (SS-OCT) is capable of measuring the central curvatures of the corneal tissue prepared for transplantation without loss of sterileness, providing insights on its refractive state. The aim of the paper is to compare in vitro SS-OCT measurements with pre-excision values. Hand-held keratometry and ultrasound pachymetry was performed on 22 corneas before excision of corneoscleral button and insertion in the vial with Eusol-C solution (AlchimiaS.r.l, Nicolò, Italy). After 12 to 36 h of hypothermic storage the corneas were examined within the vials with custom built SS-OCT system maintaining a sterile environment. The anterior and posterior central curvatures, and central corneal thickness (CCT) were measured. Rotation of the corneoscleral button was controlled by making a 6-o'clock mark during excision. Mean pre-excision CCT was 626.45 ± 28.71 µm and 468.05 ± 52.96 µm when measured with SS OCT (r = 0.55; p < 0.001). Respective values for average keratometry were 7.74 ± 0.39 mm and 7.92 ± 0.57 mm (r = 0.6; p = 0.22). Although high differences were observed in corneal thickness, keratometric radius of curvature at the flat (r = 0.42; p < 0.001) and steep (r = 0.62; p = 0.014) meridian of the anterior corneal surface, as well as corneal anterior astigmatism (r = 0.3; p < 0.001), showed good correlation with pre-excision values. SS-OCT is capable of providing quantitative evaluation of the human corneal grafts in hypothermic storage. Good correlation between curvature measurements before excision and during banking in the vial indicates its clinical utility.

Indexed as

Corneal DiseasesCorneal TransplantationCorneaCorneal PachymetryEye BanksHumansReproducibility of ResultsTomography, Optical Coherence

Identifiers

PMID36050445
PMCPMC9437096
OpenAlexW4294234008

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.