Evidence map›Paper›PMID 36047782›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2023

In vitro testing of a funnel-tip catheter with different clot types to decrease clot migration in mechanical thrombectomy.

Emily S Payne, Samantha Krost-Reuhl, Axel Heimann, Naureen Keric, Julia Masomi-Bornwasser, Tiemo Gerber, Larissa Seidman, Stefanie Kirschner, Marc A Brockmann, Yasemin Tanyildizi

Open access · greenAbstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Emily S PayneDepartment of Neuroradiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany.ORCID 0000-0002-8878-131X
Samantha Krost-ReuhlDepartment of Neuroradiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany.
Axel HeimannTranslational Animal Research Center, University Medical Center, Mainz, Germany.
Naureen KericDepartment of Neurosurgery, University Medical Center, Mainz, Germany.
Julia Masomi-BornwasserDepartment of Neurosurgery, University Medical Center, Mainz, Germany.ORCID 0000-0003-1955-9827
Tiemo GerberInstitute of Pathology, University Medical Center, Mainz, Germany.
Larissa SeidmanInstitute of Pathology, University Medical Center, Mainz, Germany.
Stefanie KirschnerDepartment of Radiation Oncology, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany.
Marc A BrockmannDepartment of Neuroradiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany.
Yasemin TanyildiziDepartment of Neuroradiology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany.
Johannes Gutenberg University Mainz · DEHeidelberg University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMechanical thrombectomy is the standard treatment for acute ischemic stroke in patients with large vessel occlusion and can be performed up to 24h after symptom onset. Despite high recanalization rates, embolism in new territories has been reported in 8.6% of the cases. Causes for this could be clot abruption during stent retrieval into the smaller opening of a standard distal access catheter, and antegrade blood flow via collaterals despite proximal balloon protection. A funnel-shaped tip with a larger internal diameter was developed to increase the rate of first-pass recanalization and to improve the safety and efficacy of mechanical thrombectomy.

methodsThis in vitro study compared the efficacy of a funnel-shaped tip with a standard tip in combination with different clot compositions. Mechanical thrombectomy was performed 80 times for each tip, using two stent retrievers (Trevo XP ProVue 3/20 mm, 4/20 mm) and four different clot types (hard vs. soft clots, 0-24h vs. 72h aged clots).

resultsSignificantly higher first-pass recanalization rates (mTICI 3) were observed for the funnel-shaped tip, 70.0% versus 30.0% for the standard tip (absolute difference, 32; relative difference 57.1%; P < .001), regardless of the clot type and stent retriever. Recanalization could be increased using harder Chandler loop clots versus softer statically generated clots, as well as 0-24h versus 72h aged clots, respectively.

conclusionThe funnel-shaped tip achieved higher first-pass recanalization rates than the smaller standard tip and lower rates of clot abruption at the tip. Clot compositions and aging times impacted recanalization rates.

Indexed as

Ischemic StrokeStrokeThrombosisAgedCathetersHumansIn Vitro TechniquesStentsThrombectomyTreatment Outcomeblood coagulationcathetersembolectomyIschemic stroke

Identifiers

PMID36047782
PMCPMC10680968
OpenAlexW4294026395

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.