Evidence map›Paper›PMID 36046917›Full record

ArticleMagnetic resonance in medicine2022

Investigating the impact of RF saturation-pulse parameters on compartment-selective gas-phase depolarization with xenon polarization transfer contrast MRI.

Tahmina Achekzai, Kai Ruppert, Luis Loza, Faraz Amzajerdian, Harrilla Profka, Ian F Duncan, Stephen J Kadlecek, Rahim R Rizi

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Preclinical MRI Using HyperpolarizedMolecules (Basel, Switzerland) · 2022
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Tahmina AchekzaiDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.ORCID 0000-0001-7838-3599
Kai RuppertDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.ORCID 0000-0002-7292-6019
Luis LozaDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Faraz AmzajerdianDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.ORCID 0000-0002-1326-9581
Harrilla ProfkaDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Ian F DuncanDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Stephen J KadlecekDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
Rahim R RiziDepartment of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA.

Funding

Improving lung transplant outcomes through the use of imaging in a DBD rat modelR01HL142258 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI RIZI, RAHIM R · 2018 to 2021
$3.1M
Prediction and assessment of COPD lung volume reduction outcomes with polarized MRIR01HL129805 · NHLBI · UNIVERSITY OF PENNSYLVANIA · PI RIZI, RAHIM R · 2016 to 2019
$3.0M
NHLBI NIH HHS R01 HL129805NHLBI NIH HHS R01 HL142258
6 · The paper itself

Abstract

purposeTo demonstrate the utility of continuous-wave (CW) saturation pulses in xenon-polarization transfer contrast (XTC) MRI and MRS, to investigate the selectivity of CW pulses applied to dissolved-phase resonances, and to develop a correction method for measurement biases from saturation of the nontargeted dissolved-phase compartment.

methodsStudies were performed in six healthy Sprague-Dawley rats over a series of end-exhale breath holds. Discrete saturation schemes included a series of 30 Gaussian pulses (8 ms FWHM), spaced 25 ms apart; CW saturation schemes included single block pulses, with variable flip angle and duration. In XTC imaging, saturation pulses were applied on both dissolved-phase resonance frequencies and off-resonance, to correct for other sources of signal loss and compromised selectivity. In spectroscopy experiments, saturation pulses were applied at a set of 19 frequencies spread out between 185 and 200 ppm to map out modified z-spectra.

resultsBoth modified z-spectra and imaging results showed that CW RF pulses offer sufficient depolarization and improved selectivity for generating contrast between presaturation and postsaturation acquisitions. A comparison of results obtained using a variety of saturation parameters confirms that saturation pulses applied at higher powers exhibit increased cross-contamination between dissolved-phase resonances.

conclusionUsing CW RF saturation pulses in XTC contrast preparation, with the proposed correction method, offers a potentially more selective alternative to traditional discrete saturation. The suppression of the red blood cell contribution to the gas-phase depolarization opens the door to a novel way of quantifying exchange time between alveolar volume and hemoglobin.

Indexed as

XenonXenon IsotopesAnimalsLungMagnetic Resonance ImagingRatsRats, Sprague-DawleyXenonXenon Isotopescontinuous-wave (CW) pulsedissolved-phase imaginghyperpolarized xenon-129pulmonary gas exchange

Identifiers

PMID36046917
PMCPMC9529921

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.