ArticleJournal of clinical and experimental dentistry2022

Polyethylene terephthalate clamps: Optimization in endodontic and restorative practices.

Anna-Flávia Ferreira E Cunha, Isabela-Ribeiro Madalena, Erika-Calvano Küchler, Tiago-Lima Pereira, Richard Honorato, Fernando-Carlos-Hueb de Menezes, César-Penazzo Lepri, Maria-Angélica-Hueb-de Menezes Oliveira

Abstract read
In one paragraph

Article in Journal of clinical and experimental dentistry, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Anna-Flávia Ferreira E CunhaDepartment of Biomaterials, University of Uberaba - UNIUBE, Uberaba, Minas Gerais, Brazil.
Isabela-Ribeiro MadalenaDepartment of Dentistry, University of Joinville Region, Joinville, Santa Catarina, Brazil.
Erika-Calvano KüchlerDepartment of Orthodontics, University of Regensburg, Regensburg, Germany.
Tiago-Lima PereiraDepartment of Biomaterials, University of Uberaba - UNIUBE, Uberaba, Minas Gerais, Brazil.
Richard HonoratoDepartment of Biomaterials, University of Uberaba - UNIUBE, Uberaba, Minas Gerais, Brazil.
Fernando-Carlos-Hueb de MenezesDepartment of Biomaterials, University of Uberaba - UNIUBE, Uberaba, Minas Gerais, Brazil.
César-Penazzo LepriDepartment of Biomaterials, University of Uberaba - UNIUBE, Uberaba, Minas Gerais, Brazil.
Maria-Angélica-Hueb-de Menezes OliveiraDepartment of Biomaterials, University of Uberaba - UNIUBE, Uberaba, Minas Gerais, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: There is a growing search for innovations in dental materials and instruments and, therefore, an increase need to optimize the instruments used in the absolute isolation. The gold standard procedure contributes significantly to the quality of restorative and endodontic procedures. Thus, the aim of the present study was to evaluate the radiopacity of polyethylene terephthalate polymer clamps and compare them to conventional metal clamps. Material and Methods: The polyethylene terephthalate clamp was developed at the University of Uberaba (Patent application #PI0901719-4, Uberaba, MG, Brazil). Five polyethylene terephthalate clamps and five conventional metal clamps were used. The clamps were positioned, next to an aluminum scale, under the same phosphor plate to perform 3 radiographs. The locator cylinder was set perpendicular to the radiographic films at a focal length of 20 cm and set to 60 kVp and 0.06 seconds. After image processing, optical density values were read using DBWin 5.0.4 software. The mean of the 3 readings taken on each clamp was adopted as the radiodensity of the specimen. The differences between the groups were compared using Student's t-test ( Results: Polyethylene terephthalate clamps demonstrated significantly lower radiopacity than conventional metal clamps ( Conclusions: Polyethylene terephthalate clamps have lower radiopacity when compared to conventional metal clamps.