Evidence map›Paper›PMID 36045053›Full record

ArticleAnnals of laboratory medicine2023

Clinical Usefulness of Ultraperformance Liquid Chromatography-Tandem Mass Spectrometry Method for Low Serum Testosterone Measurement.

Sung-Eun Cho, Jungsun Han, Ju-Hee Park, Euna Park, Geun Young Kim, Jun Hyung Lee, Ahram Yi, Sang Gon Lee, Eun Hee Lee, Yeo-Min Yun

Open access · diamondAbstract read
In one paragraph

Article in Annals of laboratory medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Sung-Eun ChoDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0001-8082-3100
Jungsun HanDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0003-1160-0776
Ju-Hee ParkDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0002-3751-4086
Euna ParkDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0002-3230-1364
Geun Young KimDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0002-5867-5655
Jun Hyung LeeDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0002-8682-3694
Ahram YiDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0002-3107-936X
Sang Gon LeeDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0002-4672-5811
Eun Hee LeeDepartment of Laboratory Medicine, GCLabs, Yongin, Korea.ORCID 0000-0002-2517-175X
Yeo-Min YunDepartment of Laboratory Medicine, Konkuk University Medical Center, Konkuk University School of Medicine, Seoul, Korea.ORCID 0000-0002-5485-8331
Konkuk University Medical Center · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Mass spectrometry methods exhibit higher accuracy and lower variability than immunoassays at low testosterone concentrations. We developed and validated an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for quantifying serum total testosterone. Methods: We used an ExionLC UPLC (Sciex, Framingham, MA, USA) system and a Sciex Triple Quad 6500+ (Sciex) MS/MS system in electrospray ionization and positive ion modes with multiple reaction monitoring transitions to evaluate precision, accuracy, linearity, lower limit of quantitation (LLOQ), carryover, ion suppression, stability, and reference intervals. For method comparison, we measured serum testosterone concentrations using this method in 40 subjects whose testosterone concentrations ranged from 0.14 to 55.48 nmol/L as determined using the Architect i2000 immunoassay (Abbott Diagnostics, Abbott Park, IL, USA) and in an additional 160 sera with testosterone concentrations <1.67 nmol/L. Results: The intra- and inter-run precision CVs were <2.81%, and the accuracy bias values were <3.85%, which were all acceptable. The verified linear interval was 0.03-180.84 nmol/L; the LLOQ was 0.03 nmol/L. No significant carryover and ion suppression were observed. The testosterone in serum was stable at 4°C, at -20°C, and after three freeze-thaw cycles. The reference intervals were successfully verified. The correlation was good at testosterone concentrations of 0.14-55.48 nmol/L; however, the Architect assay showed positive percent bias at concentrations <1.67 nmol/L. Conclusions: The UPLC-MS/MS assay shows acceptable performance, with a lower LLOQ than the immunoassay. This method will enable the quantitation of low testosterone concentrations.

Indexed as

Tandem Mass SpectrometryTestosteroneChromatography, LiquidHumansImmunoassayReference ValuesReproducibility of ResultsTestosteronePerformanceQuantitationTandem mass spectrometryTestosterone

Identifiers

PMID36045053
PMCPMC9467846
OpenAlexW4294124887

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.