Image quality and subject experience of quiet T1-weighted 7-T brain imaging using a silent gradient coil.

Sarah M Jacobs, Edwin Versteeg, Anja G van der Kolk, Leonie N C Visser, Ícaro A F Oliveira, Emiel van Maren, Dennis W J Klomp, Jeroen C W Siero

Abstract read
In one paragraph

Article in European radiology experimental, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sarah M Jacobs *Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands. s.m.jacobs@umctrecht.nl.ORCID 0000-0003-0147-9511
Edwin Versteeg *Department of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands. e.versteeg-5@umcutrecht.nl.
Anja G van der KolkDepartment of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.
Leonie N C VisserDepartment of Neurology, Alzheimer Center Amsterdam, Amsterdam Neuroscience, Vrije Universiteit Amsterdam, Amsterdam UMC, Amsterdam, the Netherlands.
Ícaro A F OliveiraSpinoza Centre for Neuroimaging Amsterdam, Amsterdam, the Netherlands.
Emiel van MarenDepartment of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.
Dennis W J KlompDepartment of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.
Jeroen C W SieroDepartment of Radiology and Nuclear Medicine, University Medical Center Utrecht, Utrecht, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAcoustic noise in magnetic resonance imaging (MRI) negatively impacts patients. We assessed a silent gradient coil switched at 20 kHz combined with a T

methodsFive healthy subjects (21-29 years; three females) without previous 7-T MRI experience underwent both a quiet MPRAGE (Q-MPRAGE) and conventional MPRAGE (C-MPRAGE) sequence twice. Image quality was assessed quantitatively, and qualitatively by two neuroradiologists. Sound level was measured objectively and rated subjectively on a 0 to 10 scale by all subjects immediately following each sequence and after the whole examination (delayed). All subjects also reported comfort level, overall experience and willingness to undergo the sequence again.

resultsCompared to C-MPRAGE, Q-MPRAGE showed higher signal-to-noise ratio (10%; p = 0.012) and lower contrast-to-noise ratio (20%; p < 0.001) as well as acceptable to good image quality. Q-MPRAGE produced 27 dB lower sound level (76 versus 103 dB). Subjects reported lower sound level for Q-MPRAGE both immediate (4.4 ± 1.4 versus 6.4 ± 1.3; p = 0.007) and delayed (4.6 ± 1.4 versus 6.3 ± 1.3; p = 0.005), while they rated comfort level (7.4 ± 1.0 versus 6.1 ± 1.7; p = 0.016) and overall experience (7.6 ± 1.0 versus 6.0 ± 0.9; p = 0.005) higher. Willingness to undergo the sequence again was also higher, however not significantly (8.1 ± 1.0 versus 7.2 ± 1.3; p = 0.066).

conclusionQ-MPRAGE using a silent gradient coil reduced sound level by 27 dB compared to C-MPRAGE at 7 T while featuring acceptable-to-good image quality and a quieter and more pleasant subject experience.

Indexed as

BrainMagnetic Resonance ImagingAcousticsFemaleHumansNeuroimagingSignal-To-Noise RatioAcousticsHealthy volunteersMagnetic resonance imagingNeuroimagingNoise

Identifiers

PMID36042139
PMCPMC9428090

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.