Evidence map›Paper›PMID 36041490›Full record

ArticleThe Korean journal of parasitology2022

An Evaluation of a New Quantitative Point-of Care Diagnostic to Measure Glucose-6-phosphate Dehydrogenase Activity.

Young Yil Bahk, Seong Kyu Ahn, Heung Jin Jeon, Byoung-Kuk Na, Sung-Keun Lee, Ho-Joon Shin

Open access · diamondAbstract read
In one paragraph

Article in The Korean journal of parasitology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it, 2 citations in OpenAlex.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 5 institutions in 1 country.

Young Yil BahkDepartment of Biotechnology, College of Biomedical and Health Science, Konkuk University, Chungju 27478, Korea.
Seong Kyu AhnInfectious Diseases Investigation Division, Jeonnam Institute of Public Health and Environment, Muan 58568, Korea.
Heung Jin JeonInfection Control Convergence Research Center, Chungnam National University College of Medicine, Deajeon 35015, Korea.
Byoung-Kuk NaDepartment of Parasitology and Tropical Medicine, Institute of Health Sciences, College of Medicine, Gyeongsang National University, Jinju 52727, Korea.
Sung-Keun LeeDepartment of Pharmacology, Inha University School of Medicine, Incheon 22212, Korea.
Ho-Joon ShinDepartment of Microbiology, Ajou University School of Medicine, Suwon 16499, Korea.
Ajou University · KRChungnam National University · KRGyeongsang National University · KRInha University · KRKonkuk University · KR

Funding

Ministry of Science and ICTNational Research Foundation of Korea 2020R1F1A1070882National Research Foundation of Korea 2022R1F1A1066481, 2018M3A9H5055614
6 · The paper itself

Abstract

Malaria continues to be one of the most crucial infectious burdens in endemic areas worldwide, as well as for travelers visiting malaria transmission regions. It has been reported that 8-aminoquinolines are effective against the Plasmodium species, particularly primaquine, for anti-hypnozoite therapy in P. vivax malaria. However, primaquine causes acute hemolytic anemia in individuals with glucose-6-phosphate dehydrogenase (G6PD) deficiency. Therefore, G6PD deficiency testing should precede hypnozoite elimination with 8-aminoquinoline. Several point-of-care devices have been developed to detect G6PD deficiency. The aim of the present study was to evaluate the performance of a novel, quantitative G6PD diagnostics based on a metagenomic blue fluorescent protein (mBFP). We comparatively evaluated the sensitivity and specificity of the G6PD diagnostic modality with standard methods using 120 human whole blood samples. The G6PD deficiency was spectrophotometrically confirmed. The performance of the G6PD quantitative test kit was compared with that of a licensed control medical device, the G6PD strip. The G6PD quantitative test kit had a sensitivity of 95% (95% confidence interval (CI): 89.3-100%) and a specificity of 100% (95% CI: 94.3-100%). This study shows that the novel diagnostic G6PD quantitative test kit could be a cost-effective and time-efficient, and universally mandated screening tool for G6PD deficiency.

Indexed as

AntimalarialsGlucosephosphate Dehydrogenase DeficiencyMalariaMalaria, VivaxGlucosephosphate DehydrogenaseHumansPoint-of-Care SystemsPrimaquineReagent Kits, DiagnosticAntimalarialsGlucosephosphate DehydrogenasePrimaquineReagent Kits, DiagnosticdiagnosticsG6PD deficiencymalaria treatmentmBFPprimaquine

Identifiers

PMID36041490
PMCPMC9441449
OpenAlexW4293218872

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.