Online geometry calibration for retrofit computed tomography from a mouse rotation system and a small-animal imager.

Huanyi Zhou, Stanley Reeves, Cheng-Ying Chou, Andrew Brannen, Peter Panizzi

Abstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Huanyi ZhouElectrical and Computer Engineering Department, Auburn University, Auburn, Alabama, USA.ORCID https://orcid.org/0000-0002-4678-9305
Stanley ReevesElectrical and Computer Engineering Department, Auburn University, Auburn, Alabama, USA.ORCID https://orcid.org/0000-0002-9392-2391
Cheng-Ying ChouDepartment of Biomechatronics Engineering, National Taiwan University, Taipei, Taiwan.ORCID https://orcid.org/0000-0002-5737-6960
Andrew BrannenDrug Discovery and Development, Harrison College of Pharmacy, Auburn University, Auburn, Alabama, USA.ORCID https://orcid.org/0000-0002-1318-2304
Peter PanizziDrug Discovery and Development, Harrison College of Pharmacy, Auburn University, Auburn, Alabama, USA.ORCID https://orcid.org/0000-0003-0141-8807

Funding

Pathogen specific imaging of endocarditisR01HL114477 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI NAHRENDORF, MATTHIAS, PANIZZI, PETER ROLF · 2013 to 2016
$1.7M
NHLBI NIH HHS R01 HL114477NIH HHS R01HL114477
6 · The paper itself

Abstract

backgroundComputed tomography (CT) generates a three-dimensional rendering that can be used to interrogate a given region or desired structure from any orientation. However, in preclinical research, its deployment remains limited due to relatively high upfront costs. Existing integrated imaging systems that provide merged planar X-ray also dwarfs CT popularity in small laboratories due to their added versatility. PURPOSE: In this paper, we sought to generate CT-like data using an existing small-animal X-ray imager with a specialized specimen rotation system, or MiSpinner. This setup conforms to the cone-beam CT (CBCT) geometry, which demands high spatial calibration accuracy. Therefore, a simple but robust geometry calibration algorithm is necessary to ensure that the entire imaging system works properly and accurately.

methodsBecause the rotation system is not permanently affixed, we propose a structure tensor-based two-step online (ST-TSO) geometry calibration algorithm. Specifically, two datasets are needed, namely, calibration and actual measurements. A calibration measurement detects the background of the system forward X-ray projections. A study on the background image reveals the characteristics of the X-ray photon distribution, and thus, provides a reliable estimate of the imaging geometry origin. Actual measurements consisted of an X-ray of the intended object, including possible geometry errors. A comprehensive image processing technique helps to detect spatial misalignment information. Accordingly, the first processing step employs a modified projection matrix-based calibration algorithm to estimate the relevant geometric parameters. Predicted parameters are then fine-tuned in a second processing step by an iterative strategy based on the symmetry property of the sum of projections. Virtual projections calculated from the parameters after two-step processing compensate for the scanning errors and are used for CT reconstruction. Experiments on phantom and mouse imaging data were performed to validate the calibration algorithm.

resultsOnce system correction was conducted, CBCT of a CT bar phantom and a cohort of euthanized mice were analyzed. No obvious structure error or spatial artifacts were observed, validating the accuracy of the proposed geometry calibration method. Digital phantom simulation indicated that compared with the preset spatial values, errors in the final estimated parameters could be reduced to 0.05° difference in dominant angle and 0.5-pixel difference in dominant axis bias. The in-plane resolution view of the CT-bar phantom revealed that the resolution approaches 150

conclusionsA constrained two-step online geometry calibration algorithm has been developed to calibrate an integrated X-ray imaging system, defined by a first-step analytical estimation and a second-step iterative fine-tuning. Test results have validated its accuracy in system correction, thus demonstrating the potential of the described system to be modified and adapted for preclinical research.

Indexed as

Cone-Beam Computed TomographyTomography, X-Ray ComputedAlgorithmsAnimalsCalibrationImage Processing, Computer-AssistedMicePhantoms, ImagingCT preprocessingonline geometry calibrationpreclinical CBCT

Identifiers

PMID36039982
PMCPMC9868046

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.