Evidence map›Paper›PMID 36039123›Full record

ArticleCureus2022

Laboratory-Reported Normal Value Ranges Should Not Be Used to Diagnose Periprosthetic Joint Infection.

Salvador A Forte, Joseph A D'Alonzo, Zachary Wells, Brett Levine, Stephen Sizer, Carl Deirmengian

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 4 institutions in 1 country.

Salvador A ForteOrthopedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, USA.
Joseph A D'AlonzoOrthopedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, USA.
Zachary WellsOrthopedic Surgery, Philadelphia College of Osteopathic Medicine, Philadelphia, USA.
Brett LevineOrthopedic Surgery, Rush University Medical Center, Chicago, USA.
Stephen SizerOrthopedic Surgery, Thomas Jefferson University, Philadelphia, USA.
Carl DeirmengianOrthopedic Surgery, The Rothman Orthopedic Institute, Philadelphia, USA.
Rothman Orthopaedics · USRush University Medical Center · USPhiladelphia College of Osteopathic Medicine · USRothman Institute · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionClinical laboratories offer several multipurpose tests, such as the erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP), which are not intended to diagnose any specific disease but are used by clinicians in multiple fields. The results and laboratory interpretation (normal/abnormal) of these multipurpose tests are based on laboratory-reported normal thresholds, which vary across clinical laboratories. In 2018, the International Consensus Meeting on Musculoskeletal Infection (2018 ICM) provided a gold-standard definition to diagnose periprosthetic joint infection (PJI) which included many multipurpose laboratory tests, along with thresholds optimized to diagnose PJI. The discrepancy between laboratory-reported normal thresholds and 2018 ICM-recommended PJI-optimized test thresholds has never been studied. The purpose of this study was to assess the existing variation in laboratory-reported normal thresholds for tests commonly used to diagnose PJI and evaluate the potential diagnostic impact of using laboratory-reported normal thresholds instead of 2018 ICM-recommended PJI-optimized thresholds.

methodsClinical laboratories (N=85) were surveyed to determine the laboratory-reported units of measure and normal thresholds for common multipurpose tests to diagnose PJI, including the ESR, CRP, D-dimer, synovial fluid white blood cells (SF-WBC), and polymorphonuclear cell percent (SF-PMN%). The variability of units of measure and normal thresholds for each test was then assessed among the 85 included clinical laboratories. A representative dataset from patients awaiting a revision arthroplasty was used to determine the clinical significance of the existing discrepancy between laboratory-reported normal test interpretations and 2018 ICM-recommended PJI-optimized test interpretations.

resultsTwo units of measure for the CRP and six units of measure for the D-dimer were observed, with only 59% of laboratories reporting the CRP in terms of mg/L and only 16% reporting the D-dimer in ng/ml, as needed to utilize the 2018 ICM definition of PJI. Across clinical laboratories surveyed, the mean laboratory-reported normal thresholds for the ESR (20 mm/h), CRP (7.69 mg/L), D-dimer (500 ng/mL), SF-WBC (5 cells/uL), and SF-PMN% (25%) were substantially lower than the 2018 ICM-recommended PJI-optimized thresholds of 30 mm/h, 10 mg/L, 860 ng/mL, 3,000 cells/uL, and 70%, respectively. Interpretation of test results from a representative PJI dataset using each laboratory's normal test thresholds yielded mean false-positive rates of 14% (ESR), 18% (CRP), 42% (D-dimer), 93% (SF-WBC), and 36% (SF-PMN%) versus the ICM-recommended PJI-optimized thresholds.

conclusionWhen reporting the results for multipurpose laboratory tests, such as the ESR, CRP, D-dimer, SF-WBC, and SF-PMN%, clinical laboratories utilize laboratory-reported units of measure and normal thresholds that are not intended to diagnose PJI, and therefore may not match the 2018 ICM recommendations. Our findings reveal that laboratory-reported normal thresholds for these multipurpose tests are well below the 2018 ICM recommendations to diagnose PJI. Clinical reliance on laboratory-reported results and interpretations, instead of strict use of the 2018 ICM-recommended units and PJI-optimized thresholds, may lead to false-positive interpretation of multipurpose laboratory tests.

Indexed as

diagnosisinfectionlaboratorypjithatka

Identifiers

PMID36039123
PMCPMC9394221
OpenAlexW4292616428

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.