Evidence map›Paper›PMID 36033722›Full record

ArticleACS omega2022

Magnetic Control-Enhanced Lateral Flow Technique for Ultrasensitive Nucleic Acid Target Detection.

Wen Ren, Joseph Irudayaraj

Abstract read
In one paragraph

Article in ACS omega, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Wen RenDepartment of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.
Joseph IrudayarajDepartment of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States.ORCID https://orcid.org/0000-0002-0630-1520

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this work, a lateral flow (LF)-based detection strategy termed magnetic control-enhanced LFA (MCLF) was proposed to detect nucleic acid sequences at attomolar sensitivity. In the proposed MCLF method, magnetic controllers which are magnetic nanoparticles modified with antibodies against the labels on capture sequences were used to interact with the unreacted labeled capture sequence (CS-label) to improve the detection limit. By regulating the movement of magnetic probes (magnetic controllers) with a simple magnet under the lateral flow strip, the movement of magnetic probes bounded with unreacted CS-label in the sample flow could be reduced. Therefore, the target sequence-containing sandwich structures will arrive at the test zone prior, to interact with the recognition ligands, whereby the capture efficiency of the sandwich structures could be increased because the unreacted capture sequences at the test zone will be reduced. With the colorimetric signal from gold nanoparticle-based probes, the proposed MCLF technique could recognize as low as 100 aM of DNA target sequences by naked eyes, and the responding range of MCLF is from 100 aM to 10 pM.

Identifiers

PMID36033722
PMCPMC9404192

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.