Evidence map›Paper›PMID 36032568›Full record

ArticleBiomedical optics express2022

Simultaneous detection of circulating tumor DNAs using a SERS-based lateral flow assay biosensor for point-of-care diagnostics of head and neck cancer.

Guang Li, Shengjie Ge, Ping Niu, Jianyou Zhang, Yu Mao, Youwei Wang, Aidong Sun

Abstract read
In one paragraph

Article in Biomedical optics express, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Guang LiDepartment of Otorhinolaryngology-Head and Neck Surgery, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225001, P. R., China.
Shengjie GeDepartment of Otorhinolaryngology-Head and Neck Surgery, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225001, P. R., China.
Ping NiuDepartments of Otolaryngology, Qingzhou People's Hospital, Qingzhou, 262500, P. R., China.
Jianyou ZhangDepartment of Anesthesiology, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225001, P. R., China.
Yu MaoInstitute of Translational Medicine, Medical College, Yangzhou University, Yangzhou, 225001, P. R., China.
Youwei WangDepartment of Neurosurgery, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225001, P. R., China.
Aidong SunDepartment of Otorhinolaryngology-Head and Neck Surgery, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, 225001, P. R., China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Circulating tumor DNA (ctDNA) has recently emerged as an ideal target for biomarker analytes. Thus, the development of rapid and ultrasensitive ctDNA detection methods is essential. In this study, a high-throughput surface-enhanced Raman scattering (SERS)-based lateral flow assay (LFA) strip is proposed. The aim of this method is to achieve accurate quantification of TP53 and PIK3CA E545K, two types of ctDNAs associated with head and neck squamous cell carcinoma (HNSCC), particularly for point-of-care testing (POCT). Raman reporters and hairpin DNAs are used to functionalize the Pd-Au core-shell nanorods (Pd-AuNRs), which serve as the SERS probes. During the detection process, the existence of targets could open the hairpins on the surface of Pd-AuNRs and trigger the first step of catalytic hairpin assembly (CHA) amplification. The next stage of CHA amplification is initiated by the hairpins prefixed on the test lines, generating numerous "hot spots" to enhance the SERS signal significantly. By the combination of high-performing SERS probes and a target-specific signal amplification strategy, TP53 and PIK3CA E545K are directly quantified in the range of 100 aM-1 nM, with the respective limits of detection (LOD) calculated as 33.1 aM and 20.0 aM in the PBS buffer and 37.8 aM and 23.1 aM in human serum, which are significantly lower than for traditional colorimetric LFA methods. The entire detection process is completed within 45 min, and the multichannel design realizes the parallel detection of multiple groups of samples. Moreover, the analytical performance is validated, including reproducibility, uniformity, and specificity. Finally, the SERS-LFA biosensor is employed to analyze the expression levels of TP53 and PIK3CA E545K in the serum of patients with HNSCC. The results are verified as consistent with those of qRT-PCR. Thus, the SERS-LFA biosensor can be considered as a noninvasive liquid biopsy assay for clinical cancer diagnosis.