Observational studyThe Lancet. Digital health2022
Clinical validation of deep learning algorithms for radiotherapy targeting of non-small-cell lung cancer: an observational study.
Observational study in The Lancet. Digital health, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 35 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
35 citing papers in PubMed.
- Artificial Intelligence Tools in Precision Lung Cancer Care: From Early Detection to Clinical Decision Support.Cancers · 2026Review
- A prospective multicenter trial of deep learning auto-segmentation for organs at risk in thoracic radiotherapy.Nature communications · 2026Observational
- Recent applications of artificial intelligence in cancer radiotherapy and immunotherapy: current status and future directions.Frontiers in immunology · 2026Review
- AI Revolution in Radiology, Radiation Oncology and Nuclear Medicine: Transforming and Innovating the Radiological Sciences.Journal of medical imaging and radiation oncology · 2025Review
- A comprehensive multifaceted technical evaluation framework for implementation of auto-segmentation models in radiotherapy.Communications medicine · 2025Article
- Article
- A Thorough Review of the Clinical Applications of Artificial Intelligence in Lung Cancer.Cancers · 2025Review
- Article
- Deep learning architectures for influenza dynamics and treatment optimization: a comprehensive review.Frontiers in artificial intelligence · 2025Review
- Evaluating deep learning auto-contouring for lung radiation therapy: A review of accuracy, variability, efficiency and dose, in target volumes and organs at risk.Physics and imaging in radiation oncology · 2025Review
- LLM-driven multimodal target volume contouring in radiation oncology.Nature communications · 2024Article
- Prediction of metastases in confusing mediastinal lymph nodes based on flourine-18 fluorodeoxyglucose (Quantitative imaging in medicine and surgery · 2024Article
- Evolving Horizons in Radiation Therapy Auto-Contouring: Distilling Insights, Embracing Data-Centric Frameworks, and Moving Beyond Geometric Quantification.Advances in radiation oncology · 2024Article
- Stepwise Transfer Learning for Expert-level Pediatric Brain Tumor MRI Segmentation in a Limited Data Scenario.Radiology. Artificial intelligence · 2024Article
- Autocontouring of primary lung lesions and nodal disease for radiotherapy based only on computed tomography images.Physics and imaging in radiation oncology · 2024Article
- Deep-learning segmentation to select liver parenchyma for categorizing hepatic steatosis on multinational chest CT.Scientific reports · 2024Article
- Noninvasive Molecular Subtyping of Pediatric Low-Grade Glioma with Self-Supervised Transfer Learning.Radiology. Artificial intelligence · 2024Article
- The power of the radiologist's last word: can deep learning models accurately differentiate between high-grade gliomas and metastasis through natural language processing on radiology reports?European radiology · 2024Article
- Clinical Evaluation of Deep Learning for Tumor Delineation onJournal of nuclear medicine : official publication, Society of Nuclear Medicine · 2024Article
- Advancing equitable and personalized cancer care: Novel applications and priorities of artificial intelligence for fairness and inclusivity in the patient care workflow.European journal of cancer (Oxford, England : 1990) · 2024Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors.
Funding
Abstract
backgroundArtificial intelligence (AI) and deep learning have shown great potential in streamlining clinical tasks. However, most studies remain confined to in silico validation in small internal cohorts, without external validation or data on real-world clinical utility. We developed a strategy for the clinical validation of deep learning models for segmenting primary non-small-cell lung cancer (NSCLC) tumours and involved lymph nodes in CT images, which is a time-intensive step in radiation treatment planning, with large variability among experts.
methodsIn this observational study, CT images and segmentations were collected from eight internal and external sources from the USA, the Netherlands, Canada, and China, with patients from the Maastro and Harvard-RT1 datasets used for model discovery (segmented by a single expert). Validation consisted of interobserver and intraobserver benchmarking, primary validation, functional validation, and end-user testing on the following datasets: multi-delineation, Harvard-RT1, Harvard-RT2, RTOG-0617, NSCLC-radiogenomics, Lung-PET-CT-Dx, RIDER, and thorax phantom. Primary validation consisted of stepwise testing on increasingly external datasets using measures of overlap including volumetric dice (VD) and surface dice (SD). Functional validation explored dosimetric effect, model failure modes, test-retest stability, and accuracy. End-user testing with eight experts assessed automated segmentations in a simulated clinical setting.
findingsWe included 2208 patients imaged between 2001 and 2015, with 787 patients used for model discovery and 1421 for model validation, including 28 patients for end-user testing. Models showed an improvement over the interobserver benchmark (multi-delineation dataset; VD 0·91 [IQR 0·83-0·92], p=0·0062; SD 0·86 [0·71-0·91], p=0·0005), and were within the intraobserver benchmark. For primary validation, AI performance on internal Harvard-RT1 data (segmented by the same expert who segmented the discovery data) was VD 0·83 (IQR 0·76-0·88) and SD 0·79 (0·68-0·88), within the interobserver benchmark. Performance on internal Harvard-RT2 data segmented by other experts was VD 0·70 (0·56-0·80) and SD 0·50 (0·34-0·71). Performance on RTOG-0617 clinical trial data was VD 0·71 (0·60-0·81) and SD 0·47 (0·35-0·59), with similar results on diagnostic radiology datasets NSCLC-radiogenomics and Lung-PET-CT-Dx. Despite these geometric overlap results, models yielded target volumes with equivalent radiation dose coverage to those of experts. We also found non-significant differences between de novo expert and AI-assisted segmentations. AI assistance led to a 65% reduction in segmentation time (5·4 min; p<0·0001) and a 32% reduction in interobserver variability (SD; p=0·013).
interpretationWe present a clinical validation strategy for AI models. We found that in silico geometric segmentation metrics might not correlate with clinical utility of the models. Experts' segmentation style and preference might affect model performance.
fundingUS National Institutes of Health and EU European Research Council.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.