Evidence map›Paper›PMID 36016070›Full record

ArticleSensors (Basel, Switzerland)2022

A Signal Processing Method for Assessing Ankle Torque with a Custom-Made Electronic Dynamometer in Participants Affected by Diabetic Peripheral Neuropathy.

Iulia Iovanca Dragoi, Teodor Petrita, Florina Georgeta Popescu, Florin Alexa, Sorin Barac, Frank L Bowling, Neil D Reeves, Cosmina Ioana Bondor, Mihai Ionac

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 91% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Iulia Iovanca DragoiDepartment of Vascular Surgery and Reconstructive Microsurgery, "Victor Babes" University of Medicine and Pharmacy, 2 Eftimie Murgu Square, 300041 Timisoara, Romania.ORCID 0000-0002-1494-4841
Teodor PetritaDepartment of Communications, Politehnica University Timisoara, 2 Vasile Parvan, 300223 Timisoara, Romania.ORCID 0000-0001-7267-3069
Florina Georgeta PopescuDiscipline of Occupational Health, "Victor Babes" University of Medicine and Pharmacy, 2 Eftimie Murgu Square, 300041 Timisoara, Romania.ORCID 0000-0002-9967-2653
Florin AlexaDepartment of Communications, Politehnica University Timisoara, 2 Vasile Parvan, 300223 Timisoara, Romania.
Sorin BaracDepartment of Vascular Surgery and Reconstructive Microsurgery, "Victor Babes" University of Medicine and Pharmacy, 2 Eftimie Murgu Square, 300041 Timisoara, Romania.
Frank L BowlingDepartment of Vascular Surgery and Reconstructive Microsurgery, "Victor Babes" University of Medicine and Pharmacy, 2 Eftimie Murgu Square, 300041 Timisoara, Romania.
Neil D ReevesResearch Centre for Musculoskeletal Science & Sports Medicine, Department of Life Sciences, Faculty of Science and Engineering, Manchester Metropolitan University, Oxford Rd., Manchester M1 5GD, UK.ORCID 0000-0001-9213-4580
Cosmina Ioana BondorDepartment of Medical Informatics and Biostatistics, University of Medicine and Pharmacy "Iuliu Hațieganu", 8 Victor Babeș, 400000 Cluj-Napoca, Romania.
Mihai IonacDepartment of Vascular Surgery and Reconstructive Microsurgery, "Victor Babes" University of Medicine and Pharmacy, 2 Eftimie Murgu Square, 300041 Timisoara, Romania.
Victor Babeș University of Medicine and Pharmacy Timișoara · ROPolytechnic University of Timişoara · ROIuliu Hațieganu University of Medicine and Pharmacy · ROManchester Metropolitan University · GBUniversity of Manchester · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Portable, custom-made electronic dynamometry for the foot and ankle is a promising assessment method that enables foot and ankle muscle function to be established in healthy participants and those affected by chronic conditions. Diabetic peripheral neuropathy (DPN) can alter foot and ankle muscle function. This study assessed ankle toque in participants with diabetic peripheral neuropathy and healthy participants, with the aim of developing an algorithm for optimizing the precision of data processing and interpretation of the results and to define a reference frame for ankle torque measurement in both healthy participants and those affected by DPN. This paper discloses the software chain and the signal processing methods used for voltage-torque conversion, filtering, offset detection and the muscle effort type identification, which further allowed for a primary statistical report. The full description of the signal processing methods will make our research reproducible. The applied algorithm for signal processing is proposed as a reference frame for ankle torque assessment when using a custom-made electronic dynamometer. While evaluating multiple measurements, our algorithm permits for a more detailed parametrization of the ankle torque results in healthy participants and those affected by DPN.

Indexed as

Diabetes MellitusDiabetic NeuropathiesAnkleAnkle JointElectronicsHumansMuscle, SkeletalMuscle StrengthTorqueankle torquebiomedical signal processingdiabetic peripheral neuropathydynamometerfeature extractionlevel windowingtype II Chebyshev filter

Identifiers

PMID36016070
PMCPMC9416663
OpenAlexW4293250447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.