ArticleSensors (Basel, Switzerland)2022
MRI-Compatible Microcirculation System Using Ultrasonic Pumps for Microvascular Imaging on 3T MRI.
Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
The diagnosis of small vessel disease is attracting interest; however, it remains difficult to visualize the microvasculature using 3 Tesla (T) magnetic resonance imaging (MRI). Therefore, this study aimed to visualize the microvascular structure and measure a slow flow on 3T MRI. We developed a microcirculation system using piezoelectric pumps connected to small tubes (0.4, 0.5, 0.8, and 1.0 mm) and evaluated various MR sequences and imaging parameters to identify the most appropriate acquisition parameters. We found that the system could image small structures with a diameter of 0.5 mm or more when using a 1 m-long tube (maximal signal intensity of 241 in 1 mm, 199 in 0.8 mm, and 133 in 0.5 mm). We also found that the highest signal-to-noise ratio (SNR) appeared on 2-dimensional time-of-flight low-resolution imaging and that the flow velocity (10.03 cm/s) was similar to the actual velocity (11.01 cm/s in a flowmeter) when velocity encoding of 30 cm/s was used in a 0.8 mm-diameter tube. In conclusion, this study demonstrates that a microcirculation system can be used to image small vessels. Therefore, our results could serve as a basis for research on vessels' anatomical structure and pathophysiological function in small vessel disease.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.