Evidence map›Paper›PMID 36015704›Full record

ArticleSensors (Basel, Switzerland)2022

Process Monitoring Using Synchronized Path Infrared Thermography in PBF-LB/M.

Dennis Höfflin, Christian Sauer, Andreas Schiffler, Jürgen Hartmann

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Dennis HöfflinInstitute of Digital Engineering, University of Applied Sciences Würzburg Schweinfurt, 97070 Würzburg, Germany.
Christian SauerInstitute of Digital Engineering, University of Applied Sciences Würzburg Schweinfurt, 97070 Würzburg, Germany.
Andreas SchifflerInstitute of Digital Engineering, University of Applied Sciences Würzburg Schweinfurt, 97070 Würzburg, Germany.ORCID 0000-0002-1447-7331
Jürgen HartmannInstitute of Digital Engineering, University of Applied Sciences Würzburg Schweinfurt, 97070 Würzburg, Germany.ORCID 0000-0002-9645-5434
Technical University of Applied Sciences Würzburg-Schweinfurt · DE

Funding

Bayern Innovativ (Germany) 41-6562b/25/2-VAL-2103-0006
6 · The paper itself

Abstract

Additive manufacturing processes, particularly Laser-Based Powder Bed Fusion of Metals (PBF-LB/M), enable the development of new application possibilities due to their manufacturing-specific freedom of design. These new fields of application require a high degree of component quality, especially in safety-relevant areas. This is currently ensured primarily via a considerable amount of downstream quality control. Suitable process monitoring systems promise to reduce this effort drastically. This paper introduces a novel monitoring method in order to gain process-specific thermal information during the manufacturing process. The Synchronized Path Infrared Thermography (SPIT) method is based on two synchronized galvanometer scanners allowing high-speed and high-resolution observations of the melt pool in the SWIR range. One scanner is used to steer the laser over the building platform, while the second scanner guides the field of view of an IR camera. With this setup, the melting process is observed at different laser powers, scan speeds and at different locations with respect to the laser position, in order to demonstrate the positioning accuracy of the system and to initially gain thermal process data of the melt pool and the heat-affected zone. Therefore, the SPIT system shows a speed independent overall accuracy of ±2 Pixel within the evaluated range. The system further allows detailed thermal observation of the melt pool and the surrounding heat-affected zone.

Indexed as

LasersThermographyHot TemperatureLightMetalsMetalsadditive manufacturinggalvanometer scannermelt poolPBF-LB/Mprocess monitoringSPITSWIR

Identifiers

PMID36015704
PMCPMC9413356
OpenAlexW4293778035

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.