Evidence map›Paper›PMID 36014274›Full record

ArticleMicromachines2022

Optimization of Microchannels and Application of Basic Activation Functions of Deep Neural Network for Accuracy Analysis of Microfluidic Parameter Data.

Feroz Ahmed, Masashi Shimizu, Jin Wang, Kenji Sakai, Toshihiko Kiwa

Abstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Feroz AhmedGraduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University, 3-1-1, Tsushima-naka, Kita-ku, Okayama 700-8530, Japan.ORCID 0000-0003-2517-072X
Masashi ShimizuGraduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University, 3-1-1, Tsushima-naka, Kita-ku, Okayama 700-8530, Japan.
Jin WangGraduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University, 3-1-1, Tsushima-naka, Kita-ku, Okayama 700-8530, Japan.ORCID 0000-0001-5797-7697
Kenji SakaiGraduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University, 3-1-1, Tsushima-naka, Kita-ku, Okayama 700-8530, Japan.ORCID 0000-0002-7745-8920
Toshihiko KiwaGraduate School of Interdisciplinary Science and Engineering in Health Systems, Department of Medical Bioengineering, Okayama University, 3-1-1, Tsushima-naka, Kita-ku, Okayama 700-8530, Japan.ORCID 0000-0002-6594-2096

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The fabrication of microflow channels with high accuracy in terms of the optimization of the proposed designs, minimization of surface roughness, and flow control of microfluidic parameters is challenging when evaluating the performance of microfluidic systems. The use of conventional input devices, such as peristaltic pumps and digital pressure pumps, to evaluate the flow control of such parameters cannot confirm a wide range of data analysis with higher accuracy because of their operational drawbacks. In this study, we optimized the circular and rectangular-shaped microflow channels of a 100 μm microfluidic chip using a three-dimensional simulation tool, and analyzed concentration profiles of different regions of the microflow channels. Then, we applied a deep learning (DL) algorithm for the dense layers of the rectified linear unit (ReLU), Leaky ReLU, and Swish activation functions to train and test 1600 experimental and interpolation of data samples which obtained from the microfluidic chip. Moreover, using the same DL algorithm, we configured three models for each of these three functions by changing the internal middle layers of these models. As a result, we obtained a total of 9 average accuracy values of ReLU, Leaky ReLU, and Swish functions for a defined threshold value of 6×10-5 using the trial-and-error method. We applied single-to-five-fold cross-validation technique of deep neural network to avoid overfitting and reduce noises from data-set to evaluate better average accuracy of data of microfluidic parameters.

Indexed as

3D simulationdeep learning modelfluid dynamicsLeaky ReLUmicrofluidicsReLU dense layersswish activation functions

Identifiers

PMID36014274
PMCPMC9413860

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.