Evidence map›Paper›PMID 36014249›Full record

ArticleMicromachines2022

An Arterial Compliance Sensor for Cuffless Blood Pressure Estimation Based on Piezoelectric and Optical Signals.

Cheng-Yan Guo, Hao-Ching Chang, Kuan-Jen Wang, Tung-Li Hsieh

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution.

Cheng-Yan GuoAccurate Meditech Inc., New Taipei City 241406, Taiwan.ORCID 0000-0002-3397-6742
Hao-Ching ChangAccurate Meditech Inc., New Taipei City 241406, Taiwan.
Kuan-Jen WangAccurate Meditech Inc., New Taipei City 241406, Taiwan.
Tung-Li HsiehDepartment of Electronic Engineering, National Kaohsiung University of Science and Technology, No. 415, Jiangong Rd., Sanmin Dist., Kaohsiung City 807618, Taiwan.ORCID 0000-0002-1038-2124
National Kaohsiung University of Science and Technology

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveBlood pressure (BP) data can influence therapeutic decisions for some patients, while non-invasive devices that continuously monitor BP can provide patients with a more comprehensive BP assessment. Therefore, this study proposes a multi-sensor-based small cuffless BP monitoring device that integrates a piezoelectric sensor array and an optical sensor, which can monitor the patient's physiological signals from the radial artery.

methodBased on the Moens-Korteweg (MK) equation of the hemodynamic model, pulse wave velocity (PWV) can be correlated with arterial compliance and BP can be estimated. Therefore, the novel method proposed in this study involves using a piezoelectric sensor array to measure the PWV and an optical sensor to measure the photoplethysmography (PPG) intensity ratio (PIR) signal to estimate the participant's arterial parameters. The parameters measured by multiple sensors were combined to estimate BP based on the P-β model derived from the MK equation.

resultWe recruited 20 participants for the BP monitoring experiment to compare the performance of the BP estimation method with the regression model and the P-β model method with arterial compliance. We then compared the estimated BP with a reference device for validation. The results are presented as the error mean ± standard deviation (SD). Based on the regression model method, systolic blood pressure (SBP) was 0.32 ± 5.94, diastolic blood pressure (DBP) was 2.17 ± 6.22, and mean arterial pressure (MAP) was 1.55 ± 5.83. The results of the P-β model method were as follows: SBP was 0.75 ± 3.9, DBP was 1.1 ± 3.12, and MAP was 0.49 ± 2.82.

conclusionAccording to the results of our proposed small cuffless BP monitoring device, both methods of estimating BP conform to ANSI/AAMI/ISO 81060-2:20181_5.2.4.1.2 criterion 1 and 2, and using arterial parameters to calibrate the MK equation model can improve BP estimate accuracy. In the future, our proposed device can provide patients with a convenient and comfortable BP monitoring solution. Since the device is small, it can be used in a public place without attracting other people's attention, thereby effectively improving the patient's right to privacy, and increasing their willingness to use it.

Indexed as

diastolic blood pressureMoens–Kortewegphotoplethysmographypulse wave velocitysystolic blood pressure

Identifiers

PMID36014249
PMCPMC9413124
OpenAlexW4292263269

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.