Evidence map›Paper›PMID 36014127›Full record

ArticleMicromachines2022

Human Motion Pattern Recognition and Feature Extraction: An Approach Using Multi-Information Fusion.

Xin Li, Jinkang Liu, Yijing Huang, Donghao Wang, Yang Miao

Open access · goldAbstract read
In one paragraph

Article in Micromachines, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Xin LiSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.ORCID 0000-0002-5147-2097
Jinkang LiuSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.ORCID 0000-0001-8792-4772
Yijing HuangSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.ORCID 0000-0003-2040-2413
Donghao WangSchool of Mechanical and Materials Engineering, North China University of Technology, Beijing 100144, China.ORCID 0000-0001-8510-8456
Yang MiaoFaculty of Materials and Manufacturing, Beijing University of Technology, Beijing 100124, China.ORCID 0000-0002-4127-2980
North China University of Technology · CNBeijing University of Technology · CN

Funding

National Natural Science Foundation of China 62103007Natural Science Foundation of Beijing L202020
6 · The paper itself

Abstract

An exoskeleton is a kind of intelligent wearable device with bioelectronics and biomechanics. To realize its effective assistance to the human body, an exoskeleton needs to recognize the real time movement pattern of the human body in order to make corresponding movements at the right time. However, it is of great difficulty for an exoskeleton to fully identify human motion patterns, which are mainly manifested as incomplete acquisition of lower limb motion information, poor feature extraction ability, and complicated steps. Aiming at the above consideration, the motion mechanisms of human lower limbs have been analyzed in this paper, and a set of wearable bioelectronics devices are introduced based on an electromyography (EMG) sensor and inertial measurement unit (IMU), which help to obtain biological and kinematic information of the lower limb. Then, the Dual Stream convolutional neural network (CNN)-ReliefF was presented to extract features from the fusion sensors' data, which were input into four different classifiers to obtain the recognition accuracy of human motion patterns. Compared with a single sensor (EMG or IMU) and single stream CNN or manual designed feature extraction methods, the feature extraction based on Dual Stream CNN-ReliefF shows better performance in terms of visualization performance and recognition accuracy. This method was used to extract features from EMG and IMU data of six subjects and input these features into four different classifiers. The motion pattern recognition accuracy of each subject under the four classifiers is above 97%, with the highest average recognition accuracy reaching 99.12%. It can be concluded that the wearable bioelectronics device and Dual Stream CNN-ReliefF feature extraction method proposed in this paper enhanced an exoskeleton's ability to capture human movement patterns, thus providing optimal assistance to the human body at the appropriate time. Therefore, it can provide a novel approach for improving the human-machine interaction of exoskeletons.

Indexed as

artificial intelligenceEMGfeature extractionIMUmotion pattern recognitionwearable sensors

Identifiers

PMID36014127
PMCPMC9416603
OpenAlexW4289176422

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked