Evidence map›Paper›PMID 36013121›Full record

ArticleJournal of clinical medicine2022

ATOMS (Adjustable Trans-Obturator Male System) in Patients with Post-Prostatectomy Incontinence and Previously Treated Urethral Stricture or Bladder Neck Contracture.

Ane Ullate, Ignacio Arance, Miguel Virseda-Chamorro, Sonia Ruiz, Juliusz Szczesniewski, Carlos Téllez, Fabian Queissert, Juan F Dorado, Javier C Angulo

Open access · goldAbstract read
In one paragraph

Article in Journal of clinical medicine, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.2field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Ane UllateClinical Department, Faculty of Biomedical Science, Universidad Europea, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain.
Ignacio AranceClinical Department, Faculty of Biomedical Science, Universidad Europea, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain.
Miguel Virseda-ChamorroDepartment of Urology, Hospital Nacional de Parapléjicos, Carretera de la Peraleda, S/N, 45004 Toledo, Spain.ORCID 0000-0002-9656-6548
Sonia RuizDepartment of Urology, Hospital Universitario de Getafe, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain.
Juliusz SzczesniewskiDepartment of Urology, Hospital Universitario de Getafe, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain.
Carlos TéllezDepartment of Urology, Hospital Universitario de Getafe, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain.
Fabian QueissertDepartment of Urology and Pediatric Urology, University Hospital Muenster, 48143 Muenster, Germany.
Juan F DoradoPeRTICA Statistical Solutions, Av. Leonardo Da Vinci, 8, OF217, Getafe, 28906 Madrid, Spain.
Javier C AnguloClinical Department, Faculty of Biomedical Science, Universidad Europea, Carretera de Toledo, Km 12.500, Getafe, 28905 Madrid, Spain.ORCID 0000-0002-1735-8792
Hospital Universitario de Getafe · ESHospital Nacional de Parapléjicos · ESUniversidad Europea de Madrid · ESUniversity Hospital Münster · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

(1) Background: Male stress incontinence in patients with previously treated urethral or bladder neck stricture is a therapeutic challenge. The efficacy and safety of the adjustable trans-obturator male system (ATOMS) in these patients is unknown. (2) Methods: All patients with primary ATOMS implants in our institution between 2014 and 2021 were included. The outcomes of patients with previously treated urethral or bladder neck stricture (≥6 months before ATOMS implant) and stable 16Ch urethral caliber were compared to those without a history of stricture. The primary endpoint was the dry patient rate, defined as the pad test ≤ 20 mL/day, and complication rate, including device removal. The secondary variable was self-perceived satisfaction using the Patient Global Impression of Improvement (PGI-I) scale. Wilcoxon rank sum test, Fisher’s exact test and logistic regression were performed. (3) Results: One hundred and forty-nine consecutive patients were included, twenty-one (14%) previously treated for urethral or bladder neck stricture (seven urethroplasty, nine internal urethrotomy and five bladder neck incision). After ATOMS adjustment, 38% of the patients with treated stricture were continent compared to 83% of those without (p < 0.0001). After weighted matched observations using propensity score pairing, the proportion of continent patients without a previous stricture was 56% (p = 0.236). Complications occurred in 29% of the patients with stricture and in 20% of those without (p = 0.34). The severity of the complications was distributed evenly among the groups (p = 0.42). Regarding self-perceived satisfaction with the implant, 90% of the patients with stricture perceived the results satisfactorily (PGI-I 1−3) compared to 97% of the rest (p = 0.167). Stricture was associated with radiotherapy (p < 0.0001) and time from prostatectomy to implantation (p = 0.012). There was a moderate correlation between previous stricture and the severity of incontinence, both evaluated according to the 24-h pad test (Rho = 0.378; p < 0.0001) and the ICIQ-SF questionnaire (Rho = 0.351; p < 0.0001). Multivariate analysis for the factors predictive of failure after ATOMS adjustment revealed previous stricture (OR 4.66; 95% CI 1.2−18.87), baseline 24-h pad test (per 100 mL, OR 1.28; 95% CI 1.09−1.52) and final cushion volume (per mL, OR 1.34; 95% CI 1.19−1.55). This model predicted dryness with an AUC of 92%. After the PSMATCH procedure using a propensity score, the model remained unchanged, with the previous stricture (OR 8.05; 95% CI 1.08−110.83), baseline 24-h pad test (per 100 mL, OR 1.53; 95% CI 1.15−2.26) and final cushion volume (per mL, OR 1.45; 95% CI 1.17−2) being independent predictors and an AUC of 93%. (4) Conclusions: ATOMS can be used to treat male stress incontinence in patients with a history of stricture, although the effectiveness of the device is reduced. On the other hand, the security and perceived satisfaction were equivalent for both groups.

Indexed as

adjustable trans-obturator male systemartificial urinary sphincterfixed male slingsling failurestress urinary incontinence

Identifiers

PMID36013121
PMCPMC9410097
OpenAlexW4292566571

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked