Evidence map›Paper›PMID 36010348›Full record

ArticleDiagnostics (Basel, Switzerland)2022

STANDARD M10 SARS-CoV-2 Assay for Rapid Detection of SARS-CoV-2: Comparison of Four Real-Time PCR Assays.

Seri Jeong, Nuri Lee, Su Kyung Lee, Eun-Jung Cho, Jungwon Hyun, Min-Jeong Park, Wonkeun Song, Hyun Soo Kim

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.9field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Evaluation of analytical performance of the STANDARDEmerging microbes & infections · 2024
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Seri JeongDepartment of Laboratory Medicine, Hallym University Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1, Singil-ro, Yeongdeungpo-gu, Seoul 07441, Korea.ORCID 0000-0002-4199-7033
Nuri LeeDepartment of Laboratory Medicine, Hallym University Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1, Singil-ro, Yeongdeungpo-gu, Seoul 07441, Korea.
Su Kyung LeeDepartment of Laboratory Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, 7, Keunjaebong-gil, Hwaseong 18450, Korea.
Eun-Jung ChoDepartment of Laboratory Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, 7, Keunjaebong-gil, Hwaseong 18450, Korea.
Jungwon HyunDepartment of Laboratory Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, 7, Keunjaebong-gil, Hwaseong 18450, Korea.
Min-Jeong ParkDepartment of Laboratory Medicine, Hallym University Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1, Singil-ro, Yeongdeungpo-gu, Seoul 07441, Korea.ORCID 0000-0002-2775-2128
Wonkeun SongDepartment of Laboratory Medicine, Hallym University Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1, Singil-ro, Yeongdeungpo-gu, Seoul 07441, Korea.ORCID 0000-0001-5056-9033
Hyun Soo KimDepartment of Laboratory Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, 7, Keunjaebong-gil, Hwaseong 18450, Korea.ORCID 0000-0002-7026-6715
Hallym University Dongtan Sacred Heart Hospital · KRHallym University Kangnam Sacred Heart Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The demand for assays that can rapidly and accurately detect severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) remains high. We evaluated the performance of two rapid real-time reverse transcription polymerase chain reaction (RT-qPCR) assays (STANDARD M10 SARS-CoV-2 and Xpert Xpress SARS-CoV-2) against conventional RT-qPCR assays (STANDARD M nCoV and Allplex SARS-CoV-2) for detecting SARS-CoV-2. A total of 225 swab samples were collected and tested using the four assays. The STANDARD M10 SARS-CoV-2 assay showed 97.4% positive percent agreement (PPA) and 100.0% negative percent agreement (NPA) compared to the STANDARD M nCoV assay and Allplex SARS-CoV-2 assay. STANDARD M10 exhibited high performance except in samples with low viral loads (cycle threshold (Ct) > 30). Xpert Xpress showed PPA and NPA of 100.0% compared to the two conventional RT-qPCR assays. The kappa coefficient (Κ) showed nearly almost perfect agreement between each assay and conventional RT-qPCR assays. The correlations of Ct values between the two rapid RT-qPCR and conventional RT-qPCR assays were >0.8, indicating strong correlations. All included assays could detect SARS-CoV-2 variants, such as the Alpha, Beta, and Gamma variants. The recently developed STANDARD M10 has a shorter turnaround time and random-access detection on automated devices, thereby facilitating efficient testing in emergency settings.

Indexed as

comparisonreal-time PCRSARS-CoV-2variant

Identifiers

PMID36010348
PMCPMC9406901
OpenAlexW4293516391

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.