Evidence map›Paper›PMID 36010222›Full record

ArticleDiagnostics (Basel, Switzerland)2022

Is It Possible to Replace Conventional Radiography (CR) with a Dose Neutral Computed Tomography (CT) of the Cervical Spine in Emergency Radiology-An Experimental Cadaver Study.

Zsuzsanna Deak, Lindis Brummund, Sonja Kirchhoff, Markus Körner, Lucas Geyer, Fabian Mück, Mariano Scaglione, Maximilian Reiser, Ulrich Linsenmaier

Open access · goldAbstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 7 citations in OpenAlex.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Zsuzsanna DeakImaging Urania, Laurenzenberg 2, 1010 Wien, Austria.ORCID 0000-0001-8700-8221
Lindis BrummundDepartmant of Radiology, University Hospital LMU, Marchioninistraße 15, 81377 Munich, Germany.
Sonja KirchhoffDepartment of Forensic Medicine, Ludwig-Maximilians-University of Munich, Nußbaumstraße 26, 80336 Munich, Germany.
Markus KörnerDepartmant of Radiology, University Hospital LMU, Marchioninistraße 15, 81377 Munich, Germany.
Lucas GeyerDepartmant of Radiology, University Hospital LMU, Marchioninistraße 15, 81377 Munich, Germany.
Fabian MückDepartmant of Radiology, University Hospital LMU, Marchioninistraße 15, 81377 Munich, Germany.
Mariano ScaglioneDepartment of Radiology, University of Sassary, 07100 Sassari, Italy.ORCID 0000-0002-0910-8064
Maximilian ReiserDepartmant of Radiology, University Hospital LMU, Marchioninistraße 15, 81377 Munich, Germany.
Ulrich LinsenmaierDepartmant of Radiology, University Hospital LMU, Marchioninistraße 15, 81377 Munich, Germany.ORCID 0000-0001-5816-740X
LMU Klinikum · DELudwig-Maximilians-Universität München · DEUniversity of Sassari · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this experimental study on recently deceased human cadavers was to investigate whether (I) the radiation exposure of the cervical spine CT can be reduced comparable to a dose level of conventional radiography (CR); and (II) whether and which human body parameters can be predictive for higher dose reduction potential (in this context). MATERIALS AND

methodsSeventy serial CT scans of the cervical spine of 10 human cadavers undergoing postmortem virtual autopsy were taken using stepwise decreasing upper limits of the tube current (300 mAs, 150 mAs, 110 mAs, 80 mAs, 60 mAs, 40 mAs, and 20 mAs) at 120 kVp. An additional scan acquired at a fixed tube current of 300 mAs served as a reference. Images were reconstructed with filtered back projection and the upper (C1-4) and lower (C4-7) cervical spine were evaluated by three blinded readers for image quality, regarding diagnostic value and resolution of anatomical structures according to a semiquantitative three-point-scale. Dose values and individual physical parameters were recorded. The relationship of diagnostic IQ, dose reduction level, and patients' physical parameters were investigated. The high-contrast resolution of the applied CT protocols was tested in an additional phantom study.

resultsThe IQ of the upper cervical spine was diagnostic at 1.69 ± 0.58 mGy (CTDI) corresponding to 0.20 ± 0.07 mSv (effective dose) in all cadavers. IQ of the lower cervical spine was diagnostic at 4.77 ± 1.86 mGy corresponding to 0.560 ± 0.21 mSv (effective dose) in seven cadavers and at 2.60 ± 0.93 mGy corresponding to 0.31 ± 0.11 mSv in four cadavers. Significant correlation was detected for BMI (0.8366;

conclusionsConventional radiography can be replaced with a nearly dose-neutral CT scan of the cervical spine.

Indexed as

cervical spinecomputed tomographyconventional radiographydose indexemergency radiologytrauma patients

Identifiers

PMID36010222
PMCPMC9406668
OpenAlexW4289520983

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.