Evidence map›Paper›PMID 36009849›Full record

ArticleBiology2022

The Protective Performance of Process Operators' Protective Clothing and Exposure Limits under Low Thermal Radiation Conditions.

Ronald Heus, Boris R M Kingma, Birgit M A van Berlo, Douwe Mol, Hein A M Daanen, Kalev Kuklane

Abstract read
In one paragraph

Article in Biology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ronald HeusNetherlands Academy of Crisis Management and Fire Service Science, Team Fire Service Science, Netherlands Institute for Public Safety, Zilverstraat 91, 2718 RP Zoetermeer, The Netherlands.
Boris R M KingmaHuman Performance Department, Unit Defence, Safety and Security, Netherlands Institute for Applied Scientific Research (TNO), Kampweg 5, 3769 DE Soesterberg, The Netherlands.
Birgit M A van BerloDepartment of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Van der Boechorststraat 9, 1081 BT Amsterdam, The Netherlands.
Douwe MolHuman Performance Department, Unit Defence, Safety and Security, Netherlands Institute for Applied Scientific Research (TNO), Kampweg 5, 3769 DE Soesterberg, The Netherlands.
Hein A M DaanenDepartment of Human Movement Sciences, Faculty of Behavioural and Movement Sciences, Vrije Universiteit Amsterdam, Van der Boechorststraat 9, 1081 BT Amsterdam, The Netherlands.
Kalev KuklaneNetherlands Academy of Crisis Management and Fire Service Science, Team Fire Service Science, Netherlands Institute for Public Safety, Zilverstraat 91, 2718 RP Zoetermeer, The Netherlands.ORCID 0000-0003-3169-436X

Funding

Netherlands Standardization Institute Commissioned research
6 · The paper itself

Abstract

During the early stage of a fire, a process operator often acts as the first responder and may be exposed to high heat radiation levels. The present limit values of long- (>15 min) and short-term exposure (<5 min), 1.0 and 1.5 kW/m2, respectively, have been set using physiological models and manikin measurements. Since human validation is essentially lacking, this study investigated whether operators’ protective clothing offers sufficient protection during a short-term deployment. Twelve professional firefighters were exposed to three radiation levels (1.5, 2.0, and 2.5 kW/m2) when wearing certified protective clothing in front of a heat radiation panel in a climatic chamber (20 °C; 50% RH). The participants wore only briefs (male) or panties and a bra (female) and a T-shirt under the operators’ clothing. Skin temperatures were continuously measured at the chest, belly, forearm, thigh, and knee. The test persons had to stop if any skin temperature reached 43 °C, at their own request, or when 5 min of exposure was reached. The experiments showed that people in operators’ clothing can be safely exposed for 5 min to 1.5 kW/m2, up to 3 min to 2.0 kW/m2, and exposure to 2.5 kW/m2 or above must be avoided unless the clothing can maintain an air gap.

Indexed as

air gapexposure limitheatIR radiationpetrochemical industryprocess operatorprotective clothingskin temperaturethermal protective performance

Identifiers

PMID36009849
PMCPMC9405019

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked