Evidence map›Paper›PMID 36009691›Full record

ArticleAnimals : an open access journal from MDPI2022

Comparison of Jugular vs. Saphenous Blood Samples, Intrarater and In-Between Device Reliability of Clinically Used ROTEM S Parameters in Dogs.

Johanna Vuille-Dit-Bille, Nicole Weingand, Rahel Jud Schefer, Martina Stirn, Katja-Nicole Adamik, Justus M K Rathmann, Nadja E Sigrist

Open access · goldAbstract read
In one paragraph

Article in Animals : an open access journal from MDPI, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Evaluation of the Effect of Induced Endotoxemia on ROTEM SAnimals : an open access journal from MDPI · 2023
    Article
  4. Evaluation of Haemostasis in Dogs Affected by Resectable Malignancy.Animals : an open access journal from MDPI · 2022
    Article
  5. Evaluation of the Effect of Storage Time on ROTEM SAnimals : an open access journal from MDPI · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Johanna Vuille-Dit-BilleDivision of Small Animal Emergency and Critical Care, Department of Veterinary Clinical Medicine, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland.
Nicole WeingandDivision of Small Animal Emergency and Critical Care, Department of Veterinary Clinical Medicine, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland.
Rahel Jud ScheferDepartment for Small Animals, Vetsuisse Faculty, University of Zurich, 8057 Zurich, Switzerland.
Martina StirnDepartment for Clinical Diagnostics and Services, Vetsuisse Faculty, University of Zurich, 8057 Zurich, Switzerland.
Katja-Nicole AdamikDivision of Small Animal Emergency and Critical Care, Department of Veterinary Clinical Medicine, Vetsuisse Faculty, University of Bern, 3012 Bern, Switzerland.
Justus M K RathmannInstitute of Sociology, University of Zurich, 8050 Zurich, Switzerland.
Nadja E SigristDepartment for Small Animals, Vetsuisse Faculty, University of Zurich, 8057 Zurich, Switzerland.ORCID 0000-0002-9540-3288
University of Zurich · CHUniversity of Bern · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Rotational Thromboelastometry (ROTEM) allows for the global assessment of hemostasis in whole blood samples. Preanalytical and analytical factors may influence test results, and data about the reliability and reproducibility of lyophilized ROTEM tests are scarce. Therefore, the objective of this study was to evaluate the influence of blood collection site on ROTEM S parameters and to assess intrarater and in-between device variability. A total of thirty, healthy, staff-owned dogs were included. Blood collection and ROTEM analysis were performed by trained staff according to a standardized protocol. Extrinsically activated (tissue factor; Ex-TEM S), with the addition of cytochalasin for platelet inhibition (Fib-TEM S), and intrinsically activated (In-TEM) analyses were performed. Analysis of our data showed significant variability for various Ex-TEM S and Fib-TEM S parameters from different collection sites and intrarater and in-between device measurements. We conclude that serial monitoring with ROTEM should be performed on the same device, with blood always taken from the same collection site using a standardized blood sampling technique. While In-TEM S, apart from maximum lysis, showed very stable and reliable results, we suggest interpreting especially clotting and clot formation parameters from Ex-TEM S and Fib-TEM S tests with caution and using duplicate measurements to detect outliers and to prevent initiation of incorrect therapies.

Indexed as

caninecoagulationcoefficient of variationROTEMsampling sitethromboelastometry

Identifiers

PMID36009691
PMCPMC9405132
OpenAlexW4292262114

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.