ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2022
[Design and implementation of ratiometric fluorescence detection system for serum bilirubin].
Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The current quantitative methods of bilirubin have disadvantages such as high cost and low sensitivity. Due to the negative correlation between the level of serum bilirubin and the risk of cardiovascular diseases, a fluorescent ratiometric film sensor was developed aiming at bilirubin detection at low level concentration. Blue-emitting and red-emitting gold nanoclusters were assembled into the same film using layer-by-layer self-assembly technology. Detection of bilirubin was achieved based on the intensity ratio of the two nanoclusters. Bilirubin exposure causes fluorescent quenching of the film. The fluorescence intensity ratio of the two cluster probes had quantitative relationship versus bilirubin concentration. Based on this film sensor, a portable fluorescence detection system was designed for the ratiometric sensing of bilirubin. The hardware of the system was mainly composed of main control chip STM32F407, TSL237 and TSL238T optical frequency sensor. A light-avoiding dark room and detection light path were designed through three-dimensional printing to reduce the interference from ambient light and improve detection accuracy. Experimental results showed that the proposed detection system had strong anti-interference, good stability and accuracy. The linear coefficient of bilirubin detected by this system was 0.987. The system presented good results in reproducible experiments and possessed a good linear relationship with the data obtained by standard spectrofluorometer. The portable system is expected to detect serum bilirubin at low levels.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.