Evidence map›Paper›PMID 36008330›Full record

ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2022

[Biomechanical analysis of Magic screw fixation for acetabular posterior column fracture].

Haowei Zhang, Zihuan Xu, Ying Liu, Yongqin Wang, Pengfei Li, Hongmin Cai, Ming Ni

Open access · greenAbstract read
In one paragraph

Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. [Biomechanical study on wing shaped titanium plate fixation of acetabular anterior column and posterior hemi-transverse fracture under multiple working conditions].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Haowei ZhangSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Zihuan XuSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Ying LiuSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Yongqin WangSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Pengfei LiSchool of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, P. R. China.
Hongmin CaiDepartment of Pelvic and Acetabular Surgery, Luoyang Orthopedic-Traumatological Hospital of Henan Province (Henan Provincial Orthopedic Hospital), Luoyang, Henan 471002, P. R. China.
Ming NiDepartment of Orthopaedics, Shanghai Pudong New Area Peoples' Hospital, Shanghai 201299, P. R. China.
University of Shanghai for Science and Technology · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aims to analyze the biomechanical stability of Magic screw in the treatment of acetabular posterior column fractures by finite element analysis. A three-dimensional finite element model of the pelvis was established based on the computed tomography (CT) and magnetic resonance imaging (MRI) data of a volunteer and its effectiveness was verified. Then, the posterior column fracture model of the acetabulum was generated. The biomechanical stability of the four internal fixation models was compared. The 500 N force was applied to the upper surface of the sacrum to simulate human gravity. The maximum implant stresses of retrograde screw fixation, single-plate fixation, double-plate fixation and Magic screw fixation model in standing and sitting position were as follows: 114.10, 113.40 MPa; 58.93, 55.72 MPa; 58.76, 47.47 MPa; and 24.36, 27.50 MPa, respectively. The maximum stresses at the fracture end were as follows: 72.71, 70.51 MPa; 48.18, 22.80 MPa; 52.38, 27.14 MPa; and 34.05, 30.78 MPa, respectively. The fracture end displacement of the retrograde tension screw fixation model was the largest in both states, and the Magic screw had the smallest displacement variation in the standing state, but it was significantly higher than the two plate fixations in the sitting state. Magic screw can satisfy the biomechanical stability of posterior column fracture. Compared with traditional fixations, Magic screw has the advantages of more uniform stress distribution and less stress, and should be recommended.

Indexed as

Fractures, BoneSpinal FracturesBiomechanical PhenomenaBone PlatesBone ScrewsFinite Element AnalysisFracture Fixation, InternalHumansAcetabular fractureBiomechanicsFinite element analysisInternal fixation of fracture

Identifiers

PMID36008330
PMCPMC10957346
OpenAlexW4293866178

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked