ArticleBMJ open2022
Slowly absorbable mesh versus standard care in the management of contaminated midline incisional hernia (COMpACT-BIO): a multicentre randomised controlled phase III trial including a health economic evaluation.
Article in BMJ open, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04597840 (Multicenter, Prospective, Longitudinal and Randomized Comparison of Both the Clinical and Economic Impact of Biosynthetic Absorbable Mesh to the Surgical Standard of Care in Contaminated Incisional Hernia Repair), which is not on this map. Cited by 5 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Multicenter, Prospective, Longitudinal and Randomized Comparison of Both the Clinical and Economic Impact of Biosynthetic Absorbable Mesh to the Surgical Standard of Care in Contaminated Incisional Hernia Repair
Who cites it
5 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Synthetic vs. biologic mesh for abdominal wall reconstruction in contaminated surgical fields. A meta-analysis of randomized controlled trials and observational studies.Hernia : the journal of hernias and abdominal wall surgery · 2024Pooled it
- A scoping review of outcome reporting in randomized controlled trials of incisional and non-incisional ventral hernia repair.Hernia : the journal of hernias and abdominal wall surgery · 2026Article
- Mesh removal and ventral hernia repair with long-term absorbable mesh in case of mesh infection.Hernia : the journal of hernias and abdominal wall surgery · 2025Article
- Evidence-based, cost-effective management of abdominal wall hernias: An algorithm of the Journal of Trauma and Acute Care Surgery emergency general surgery algorithms work group.The journal of trauma and acute care surgery · 2025Article
- Slowly absorbable mesh in sublay ventral hernia repair in contaminated fields.Surgical endoscopy · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionIncisional hernia (IH) is the most frequent mid-term and long-term complication after midline laparotomy. The current standard treatment includes repair using a mesh. In a contaminated field, the use of a non-absorbable mesh increases the risk of surgical site infection and the costs. Slowly absorbable meshes are safe in contaminated fields, but no data have been reported regarding their long-term recurrence rate. COMpACT-BIO is a multicentre prospective randomised controlled phase III trial designed to compare the 3-year recurrence rate in patients undergoing contaminated IH repair with either a slowly absorbable mesh or standard care.
methodsIn patients undergoing midline IH repair in a contaminated surgical field (grade III of the modified Ventral Hernia Working Group classification), the COMpACT-BIO study compares the use of a slowly absorbable mesh with that of conventional care according to standardised surgical procedures (primary closure, non-absorbable synthetic mesh or biologic mesh, at the discretion of the surgeon). Randomisation is done during surgery before closure the fascia with an allocation ratio of 1:1. The choice of the slowly absorbable mesh is left to the criteria of each centre. The primary endpoint is the proportion of patients with scan-confirmed IH recurrence within 3 years after repair. ETHICS/DISSEMINATION: This trial is conducted in compliance with international standards for research practice and reporting. Written informed consent will be obtained from patients prior to inclusion. All data were identified and anonymised prior to analysis. The protocol has been approved by an Institutional Review Board (2020-A0823-36/SI:20.07.03.66831), and will be conducted in compliance with the CONSORT (Consolidated Standards of Reporting Trials) statement. Results will be submitted for publication in peer-reviewed medical journals and presented to patients and healthcare professionals. PROTOCOL VERSION: Version 2-13 October 2020. TRIAL REGISTRATION NUMBER: NCT04597840.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.