Evidence map›Paper›PMID 36006641›Full record

SynthesisJAMA network open2022

Small Study Effects in Diagnostic Imaging Accuracy: A Meta-Analysis.

Lucy Lu, Qi Sheng Phua, Stephen Bacchi, Rudy Goh, Aashray K Gupta, Joshua G Kovoor, Christopher D Ovenden, Minh-Son To

Abstract readMeta-Analysis
In one paragraph

Synthesis in JAMA network open, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 11 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 11 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 11 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Pooled it
  7. Pooled it
  8. Pooled it
  9. Pooled it
  10. Pooled it
  11. Pooled it
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors.

Lucy LuCollege of Medicine and Public Health, Flinders University, Bedford Park, Australia.
Qi Sheng PhuaCollege of Medicine and Public Health, Flinders University, Bedford Park, Australia.
Stephen BacchiDepartment of Neurology, Royal Adelaide Hospital, Adelaide, Australia.
Rudy GohDepartment of Neurology, Royal Adelaide Hospital, Adelaide, Australia.
Aashray K GuptaFaculty of Health and Medical Sciences, The University of Adelaide, Adelaide, Australia.
Joshua G KovoorFaculty of Health and Medical Sciences, The University of Adelaide, Adelaide, Australia.
Christopher D OvendenFaculty of Health and Medical Sciences, The University of Adelaide, Adelaide, Australia.
Minh-Son ToCollege of Medicine and Public Health, Flinders University, Bedford Park, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Small study effects are the phenomena that studies with smaller sample sizes tend to report larger and more favorable effect estimates than studies with larger sample sizes. Objective: To evaluate the presence and extent of small study effects in diagnostic imaging accuracy meta-analyses. Data Sources: A search was conducted in the PubMed database for diagnostic imaging accuracy meta-analyses published between 2010 and 2019. Study Selection: Meta-analyses with 10 or more studies of medical imaging diagnostic accuracy, assessing a single imaging modality, and providing 2 × 2 contingency data were included. Studies that did not assess diagnostic accuracy of medical imaging techniques, compared 2 or more imaging modalities or different methods of 1 imaging modality, were cost analyses, used predictive or prognostic tests, did not provide individual patient data, or were network meta-analyses were excluded. Data Extraction and Synthesis: Data extraction was performed in accordance with the PRISMA guidelines. Main Outcomes and Measures: The diagnostic odds ratio (DOR) was calculated for each primary study using 2 × 2 contingency data. Regression analysis was used to examine the association between effect size estimate and precision across meta-analyses. Results: A total of 31 meta-analyses involving 668 primary studies and 80 206 patients were included. Fixed effects analysis produced a regression coefficient for the natural log of DOR against the SE of the natural log of DOR of 2.19 (95% CI, 1.49-2.90; P < .001), with computed tomography as the reference modality. Interaction test for modality and SE of the natural log of DOR did not depend on modality (Wald statistic P = .50). Taken together, this analysis found an inverse association between effect size estimate and precision that was independent of imaging modality. Of 26 meta-analyses that formally assessed for publication bias using funnel plots and statistical tests for funnel plot asymmetry, 21 found no evidence for such bias. Conclusions and Relevance: This meta-analysis found evidence of widespread prevalence of small study effects in the diagnostic imaging accuracy literature. One likely contributor to the observed effects is publication bias, which can undermine the results of many meta-analyses. Conventional methods for detecting funnel plot asymmetry conducted by included studies appeared to underestimate the presence of small study effects. Further studies are required to elucidate the various factors that contribute to small study effects.

Indexed as

Tomography, X-Ray ComputedBiasHumansOdds RatioPublication BiasSample Size

Identifiers

PMID36006641
PMCPMC9412222

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.