Evidence map›Paper›PMID 36005428›Full record

ArticleJournal of cardiovascular development and disease2022

Overcoming High Impedance in the Transitional Area of the Distal Great Cardiac Vein during Radiofrequency Catheter Ablation of Ventricular Arrhythmia.

Yan-Ru Chen, Yi-Fan Lin, Que Xu, Cheng Zheng, Rui-Lin He, Jin Li, Jia Li, Yue-Chun Li, Jia-Xuan Lin, Jia-Feng Lin

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular development and disease, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Yan-Ru ChenDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Yi-Fan LinDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Que XuDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Cheng ZhengDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Rui-Lin HeDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Jin LiDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Jia LiDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Yue-Chun LiDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Jia-Xuan LinDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Jia-Feng LinDepartment of Cardiology, The Second Affiliated Hospital and Yuying Children's Hospital of Wenzhou Medical University, Wenzhou 325000, China.
Wenzhou Medical University · CN

Funding

National Natural Science Foundation of China 82070333Wenzhou Municipal Sci-Tech Bureau ZY2020018Zhejiang Provincial Natural Science Foundation LY21H020011
6 · The paper itself

Abstract

(1) Background: Radiofrequency catheter ablation (RFCA) is an essential treatment for ventricular arrhythmia (VA). However, high impedance in the transitional area of the distal great cardiac vein (TAODGCV) often leads to ablation failure. This study aimed to explore the factors influencing impedance and identify effective ways to reduce impedance. (2) Methods: A total of 156 patients with VA arising from the TAODGCV received RFCA therapy at our center from October 2009 to August 2021 and were retrospectively analyzed. Local impedance variation during RFCA was monitored, recorded, and analyzed. (3) Results: The impedance increased from the proximal to distal portions of the TAODGCV and decreased by increasing the saline flow rate at the same site. To overcome high impedance, we implemented the following strategies: (1) Reset the upper limit impedance to 300 Ω and accelerate the saline flow rate to 60 mL/min (effective in 118 of 144 patients); (2) turn off the upper limit impedance (effective in eleven of 21 patients); (3) use high-flow-rate irrigation devices (effective in five of 15 patients); and (4) increase the upper limit temperature (effective in six of ten patients). (4) Conclusions: In the TAODGCV, local impedance is mainly influenced by the target site location and saline flow rate. We concluded several methods to overcome the high impedance and contribute to a successful ablation.

Indexed as

distal great cardiac veinelectrophysiologyImpedanceradiofrequency catheter ablationventricular arrhythmia

Identifiers

PMID36005428
PMCPMC9410161
OpenAlexW4291465225

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.