Evidence map›Paper›PMID 36004969›Full record

ArticleBiosensors2022

Cadmium Ions' Trace-Level Detection Using a Portable Fiber Optic-Surface Plasmon Resonance Sensor.

Bianca-Georgiana Şolomonea, Luiza-Izabela Jinga, Vlad-Andrei Antohe, Gabriel Socol, Iulia Antohe

Abstract read
In one paragraph

Article in Biosensors, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. Advances in Portable Heavy Metal Ion Sensors.Sensors (Basel, Switzerland) · 2023
    Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bianca-Georgiana ŞolomoneaNational Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomiştilor Street 409, 077125 Măgurele, Ilfov, Romania.ORCID 0000-0002-7095-6193
Luiza-Izabela JingaNational Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomiştilor Street 409, 077125 Măgurele, Ilfov, Romania.ORCID 0000-0001-6789-2515
Vlad-Andrei AntoheFaculty of Physics, Research and Development Center for Materials and Electronic & Optoelectronic Devices (MDEO), University of Bucharest, Atomiştilor Street 405, 077125 Măgurele, Ilfov, Romania.ORCID 0000-0003-2298-0719
Gabriel SocolNational Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomiştilor Street 409, 077125 Măgurele, Ilfov, Romania.ORCID 0000-0002-1992-7346
Iulia AntoheNational Institute for Laser, Plasma and Radiation Physics (INFLPR), Atomiştilor Street 409, 077125 Măgurele, Ilfov, Romania.ORCID 0000-0003-3455-5816

Funding

Academy of Romanian Scientists 2021Executive Unit for Financing Higher Education, Research, Development and Innovation (UEFISCDI), Romania 590/2022 (PN-III-P2-2.1-PED-2021-3165)National Authority for Research and Innovation in the framework of 224 Nucleus Programme - LAPLAS VI 16N/08.02.2019Unitatea Executiva Pentru Finantarea Invatamantului Superior a Cercetarii Dezvoltarii si Inovarii 115/2020 PN-III-P1-269 1.1-TE-2019-0868Unitatea Executiva Pentru Finantarea Invatamantului Superior a Cercetarii Dezvoltarii si Inovarii 195/2020 PN-III-P1-1.1-PD-2019-0466
6 · The paper itself

Abstract

Environmental pollution with cadmium (Cd) is a major concern worldwide, with prolonged exposure to this toxic heavy metal causing serious health problems, such as kidney damage, cancer, or cardiovascular diseases, only to mention a few. Herein, a gold-coated reflection-type fiber optic--surface plasmon resonance (Au-coated FO-SPR) sensor is manufactured and functionalized with (i) bovine serum albumin (BSA), (ii) chitosan, and (iii) polyaniline (PANI), respectively, for the sensitive detection of cadmium ions (Cd2+) in water. Then, the three sensor functionalization strategies are evaluated and compared one at a time. Out of these strategies, the BSA-functionalized FO-SPR sensor is found to be highly sensitive, exhibiting a limit of detection (LOD) for Cd2+ detection at nM level. Moreover, the presence of Cd2+ on the FO-SPR sensor surface was confirmed by the X-ray photoelectron spectroscopy (XPS) technique and also quantified consecutively for all the above-mentioned functionalization strategies. Hence, the BSA-functionalized FO-SPR sensor is sensitive, provides a rapid detection time, and is cheap and portable, with potential applicability for monitoring trace-level amounts of Cd within environmental or potable water.

Indexed as

Drinking WaterSurface Plasmon ResonanceCadmiumFiber Optic TechnologyIonsSerum Albumin, BovineCadmiumDrinking WaterIonsSerum Albumin, Bovinebovine serum albumin (BSA)cadmium detectionchitosanfiber optic—surface plasmon resonance (FO-SPR) sensorspolyaniline (PANI)

Identifiers

PMID36004969
PMCPMC9405698

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.